-
Anesthesia and analgesia · Nov 2003
Clinical TrialPulse contour analysis for cardiac output monitoring in cardiac surgery for congenital heart disease.
- Aman Mahajan, Afshin Shabanie, Judi Turner, Michael J Sopher, and Jure Marijic.
- Department of Anesthesiology, David Geffen School of Medicine, University of California Los Angeles, Los Angeles, CA 90095, USA. amahajan@mednet.ucla.edu
- Anesth. Analg. 2003 Nov 1;97(5):1283-8.
UnlabelledConventional methods of cardiac output monitoring using pulmonary artery catheters may not be feasible in patients with congenital heart disease because of patients' small size or aberrant anatomy. We studied the accuracy of a new device, which uses pulse contour analysis to measure continuous cardiac output, in children and adults undergoing congenital heart surgery. Sixteen patients, median ages 7 yr old, were included in this prospective study. One-hundred-ninety-one data points were obtained in the pre- and postcardiopulmonary bypass periods and in the first 12 h after intensive care unit admission. We evaluated the relationship between cardiac index (CI) derived from transpulmonary thermodilution (TDCI) and CI derived from pulse contour analysis (PCCI). Bias and limits of agreement between TDCI and PCCI over all time periods were 0.1 +/- 1.94, indicating a wide dispersion of the data. Coefficient of correlation (r) between the TDCI and PCCI was 0.7. Although in previous studies, PCCI has been suggested to be accurate in adult cardiac surgery, we found it to be less reliable in our study patients, even after shunt correction. The relationships of the volume and pressure based measures of preload, intrathoracic blood volume index (ITBI), and central venous pressure with CI were also investigated. After repair, correlation (r) between PCCI or TDCI and ITBI (0.56 and 0.71, respectively) was better than that between PCCI or TDCI and CVP (0.16 and 0.11, respectively), indicating greater validity of ITBI as a measure of preload.ImplicationsOur results suggest that the pulse contour analysis cardiac output (CO) monitoring in patients undergoing congenital heart surgery may not provide as accurate or reliable measures of CO as previously suggested. The volume-based variable of preload intrathoracic blood volume index (ITBI) has better correlation with cardiac index (CI) than the central venous pressure, suggesting that ITBI may be a better indicator of preload.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.