    The detection of interatrial flow patency in awake and anesthetized patients: a comparative study using transnasal transesophageal echocardiography.

    • C A Greim, H Trautner, K Krämer, P Zimmermann, C C Apfel, and N Roewer.
    • Department of Anesthesiology, University Hospital Würzburg, Josef-Schneider-Str. 2, 97080 Würzburg, Germany. cgreim@anaesthesie.uni-wuerzburg.de
    • Anesth. Analg. 2001 May 1;92(5):1111-6.

    UnlabelledThe Valsalva maneuver in the awake patient and the ventilation maneuver in the tracheally intubated anesthetized patient are two provocation methods to detect a patent foramen ovale (PFO) by means of contrast transesophageal echocardiography. In 60 patients undergoing posterior fossa surgery, a contrast agent was administered via a peripheral vein during a Valsalva maneuver immediately before anesthesia induction, followed by central venous administration during a ventilation maneuver in the same patients when anesthetized and endotracheally intubated. We evaluated both maneuvers with a 32-element monoplane transnasal transesophageal echocardiography probe to trace the atrial flow of the contrast agent in a 90 degrees bicaval view. A maneuver was rated positive when more than four bubbles appeared in the left atrium during the first three cardiac cycles after intrathoracic pressure release. The right atrial cross-sectional area before pressure release, and the peak septal excursion during atrial contrast opacification, were measured. McNemar's test was used to assess a paired dichotomous response on the two maneuvers for a significant difference. In 56 patients, the ventilation maneuver was significantly (P < 0.037) more often positive for PFO (n = 14) than the Valsalva maneuver (n = 7). Although there was no difference in the methods regarding the peak septal excursion, the mean right atrial area before pressure release was significantly smaller during the ventilation maneuver than during the Valsalva maneuver (11.2 +/- 3.1 cm(2) vs 14.4 +/- 3.3 cm(2), n = 42, P < 0.05). In the patients with a positive ventilation, but a negative Valsalva maneuver, the discrepancy was even larger (10.9 +/- 4.4 cm(2) vs 16.3 +/- 4.2 cm(2), n = 7, P < 0.001). We conclude that the ventilation maneuver is superior to the Valsalva maneuver in detecting PFO. Our data suggest that a peak pressure of 30 cm H(2)O during the ventilation maneuver achieves a more pronounced reduction in right atrial load and allows right atrial pressure to exceed left atrial pressure when intrathoracic pressure is released.ImplicationsA controlled ventilation maneuver in anesthetized patients immediately before posterior fossa surgery may be superior to the preoperative Valsalva maneuver in detecting a patent foramen ovale by contrast transesophageal echocardiography. This approach identifies patients at high risk for paradoxic embolism, but it is not practical for preoperative identification of patients who might benefit from patent foramen ovale closure before surgery.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…