Evaluation of a transcutaneous blood gas monitoring system in critically ill dogs.
- Marie K Holowaychuk, Hiroshi Fujita, and Alexa M E Bersenas.
- Department of Clinical Studies, Ontario Veterinary College, University of Guelph, 50 Stone Road East, Guelph, ON, N1G 2W1, Canada.
- J Vet Emerg Crit Care (San Antonio). 2014 Sep 1;24(5):545-53.
ObjectivesTo describe the use of a transcutaneous blood gas monitoring system in critically ill dogs, determine if transcutaneous and arterial blood gas values have good agreement, and verify if clinical or laboratory variables are correlated with differences between transcutaneous and arterial blood gas measurements.DesignProspective observational study.SettingUniversity teaching hospital ICU.AnimalsTwenty-three client-owned dogs.InterventionsIn critically ill dogs undergoing arterial blood gas monitoring, a transcutaneous blood gas monitor was used to measure transcutaneous partial pressure of carbon dioxide (PtcCO2 ) and transcutaneous partial pressure of oxygen (PtcO2 ) values 30 minutes after sensor placement, which were compared to PaCO2 and PaO2 values measured simultaneously. Clinical and laboratory variables were concurrently recorded to determine if they were correlated with the difference between transcutaneous and arterial blood gas measurements.Measurements And Main ResultsBland-Altman analysis revealed a mean bias of 4.6 ± 26.3 mm Hg (limits of agreement [LOA]: -46.9/+56.1 mm Hg) between PtcO2 and PaO2 and a mean bias of 9.3 ± 8.5 mm Hg (LOA: -7.5/+26.0 mm Hg) between PtcCO2 and PaCO2 . The difference between PtcCO2 -PaCO2 was strongly negatively correlated with HCO3 (-) (r(2) = 0.52, P < 0.001) and PaCO2 (r(2) = 0.58, P < 0.001) and weakly positively correlated with diastolic blood pressure (r(2) = 0.21, P = 0.044), whereas the difference between PtcCO2 -PaCO2 was moderately negatively correlated with diastolic blood pressure (r(2) = 0.33, P = 0.008).ConclusionsAgreement between transcutaneous and arterial PO2 and PCO2 measurements in these critically ill dogs was inferior to that reported in similar adult and pediatric human studies. The transcutaneous monitor consistently over-estimated PaO2 and PaCO2 and should not be used to replace arterial blood gas measurements in critically ill dogs requiring blood gas interpretation.© Veterinary Emergency and Critical Care Society 2014.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.