- Kevin Pilarczyk, Jens Heckmann, Kathrin Lyskawa, Andreas Strauß, Nils Haake, Ingo Wiese, Heinz Jakob, Markus Kamler, and Nikolaus Pizanis.
- Department of Thoracic and Cardiovascular Surgery, West German Heart and Vascular Center Essen, University Hospital Essen, Essen, Germany.
- Artif Organs. 2016 Jul 1; 40 (7): 645-58.
AbstractExtracorporeal membrane oxygenation (ECMO) is used for severe acute respiratory distress syndrome. However, available ECMO systems are large and not well designed for fast delivery, emergency implantation, and interhospital transfer. Therefore, a new miniaturized oxygenator with integrated rotary blood pump (ILIAS) was developed and compared with a standard ECMO system in a large animal model. Acute lung injury was induced with repeated pulmonary saline lavage in 14 pigs until PaO2 /FiO2 -ratio was <100 mm Hg with a positive-end-expiratory-pressure of 5 mbar. Pigs were assigned to the following three groups: group 1 (n = 4): control group with conventional ventilation; group 2 (n = 5): standard vv-ECMO; group 3 (n = 5): vv-ILIAS. Gas exchange, hemodynamics, hemolysis, and coagulation activation were examined over a period of 8 h. No device failed during the observation period. PaCO2 decreased from 59.40 ± 4.14 mm Hg to 48.62 ± 4.50 mm Hg after 1 h in the ILIAS group compared with an improvement of PaCO2 from 48.86 ± 7.45 to 40.10 ± 6.02 in the conventional ECMO group (P = not significant [n.s.]). ARDS-induced respiratory acidosis was controlled promptly with a pH of 7.2 ± 0.1 at baseline increasing to 7.4 ± 0.1 in both study groups after 60 min of ECMO support. Mean carbon dioxide transfer was comparable between the conventional ECMO and ILIAS (211.36 ± 78.39 mL/min vs. 219.99 ± 76.72 mL/min, P = n.s.). PaO2 /FiO2 increased from 118.4 ± 15.5 mm Hg to 179.1 ± 72.4 mm Hg in the ILIAS group compared with an improvement of oxygenation from 107.1 ± 24.9 mm Hg to 179.0 ± 45.7 mm Hg in the standard ECMO group (P = n.s.). Mean oxygen transfer was calculated with 136.09 ± 30.25 mL/min for the ILIAS and 129.05 ± 36.28 mL/min for the standard ECMO. Hemodynamic instability or significant activation of the plasmatic coagulation was not observed. However, hemolysis was significantly higher in the ILIAS group compared with the conventional ECMO. As the ILIAS prototype provided excellent gas exchange with hemodynamic stability comparable with a standard ECMO system, we believe this study serves as a proof of concept. Further development and design modifications (optimized rotation speed and surface coating of rotor) are already done and another experiment is projected to reduce hemolysis and platelet consumption for clinical application. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.