• Artificial organs · Aug 1998

    The type of aortic cannula and membrane oxygenator affect the pulsatile waveform morphology produced by a neonate-infant cardiopulmonary bypass system in vivo.

    • A Undar, A J Lodge, C W Daggett, T M Runge, R M Ungerleider, and J H Calhoon.
    • Department of Surgery, University of Texas Health Science Center, San Antonio, USA.
    • Artif Organs. 1998 Aug 1;22(8):681-6.

    AbstractAlthough the debate still continues over the effectiveness of pulsatile versus nonpulsatile perfusion, it has been clearly proven that there are several significant physiological benefits of pulsatile perfusion during cardiopulmonary bypass (CPB) compared to nonpulsatile perfusion. However, the components of the extracorporeal circuit have not been fully investigated regarding the quality of the pulsatility. In addition, most of these results have been gathered from adult patients, not from neonates and infants. We have designed and tested a neonate-infant pulsatile CPB system using 2 different types of 10 Fr aortic cannulas and membrane oxygenators in 3 kg piglets to evaluate the effects of these components on the pulsatile waveform produced by the system. In terms of the methods, Group 1 (Capiox 308 hollow-fiber membrane oxygenator and DLP aortic cannula with a very short 10 Fr tip [n = 2]) was subjected to a 2 h period of normothermic pulsatile CPB with a pump flow rate of 150 ml/kg/min. Data were obtained at 5, 30, 60, 90, and 120 min of CPB. In Group 2 (Capiox 308 hollow-fiber membrane oxygenator and Elecath aortic cannula with a very long 10 Fr tip [n = 7]) and Group 3 (cobe VPCML Plus flat sheet membrane oxygenator and DLP aortic cannula with a very short 10 Fr tip [n = 7]), the subjects' nasopharyngeal temperatures were reduced to 18 degrees C followed by 1 h of deep hypothermic circulatory arrest (DHCA) and then 40 min rewarming. Data were obtained during normothermic CPB in the pre- and post-DHCA periods. The criteria of pulsatility evaluations were based upon pulse pressure (between 30 and 40 mm Hg), aortic dp/dt (greater than 1000 mm Hg/s), and ejection time (less than 250 ms). The results showed that Group 1 produced flow which was significantly more pulsatile than that of the other 2 groups. Although the same oxygenator was used for Group 2, the quality of the pulsatile flow decreased when using a different aortic cannula. Group 3 did not meet any of the criteria for physiologic pulsatility. In conclusion these data suggest that in addition to a pulsatile pump, the aortic cannula and the membrane oxygenator must be chosen carefully to achieve physiologic pulsatile flow during CPB.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…