Cochrane Db Syst Rev · Mar 2013
Review Meta AnalysisInterventions for replacing missing teeth: different times for loading dental implants.
- Marco Esposito, Maria Gabriella Grusovin, Hassan Maghaireh, and Helen V Worthington.
- Cochrane Oral Health Group, School of Dentistry, The University of Manchester, Manchester, UK. espositomarco@hotmail.com.
- Cochrane Db Syst Rev. 2013 Mar 28; 2013 (3): CD003878CD003878.
BackgroundTo minimise the risk of implant failures after their placement, dental implants are kept load-free for 3 to 8 months to establish osseointegration (conventional loading). It would be beneficial if the healing period could be shortened without jeopardising implant success. Nowadays implants are loaded early and even immediately and it would be useful to know whether there is a difference in success rates between immediately and early loaded implants compared with conventionally loaded implants.ObjectivesTo evaluate the effects of (1) immediate (within 1 week), early (between 1 week and 2 months), and conventional (after 2 months) loading of osseointegrated implants; (2) immediate occlusal versus non-occlusal loading and early occlusal versus non-occlusal loading; (3) direct loading versus progressive loading immediately, early and conventionally.Search MethodsThe following electronic databases were searched: the Cochrane Oral Health Group's Trials Register (to 8 June 2012), the Cochrane Central Register of Controlled Trials (CENTRAL) (The Cochrane Library, 2012, Issue 4), MEDLINE via OVID (1946 to 8 June 2012) and EMBASE via OVID (1980 to 8 June 2012). Authors of identified trials were contacted to find unpublished randomised controlled trials (RCTs). There were no restrictions regarding language or date of publication.Selection CriteriaAll RCTs of root-form osseointegrated dental implants, having a follow-up of 4 months to 1 year, comparing the same implant type immediately, early or conventionally loaded, occlusally or non-occlusally loaded, or progressively loaded or not. Outcome measures were: prosthesis and implant failures and radiographic marginal bone level changes.Data Collection And AnalysisData were independently extracted, in duplicate, by at least two review authors. Trial authors were contacted for missing information. Risk of bias was assessed for each trial by at least two review authors, and data were extracted independently, and in duplicate. Results were combined using fixed-effect models with mean differences (MD) for continuous outcomes and risk ratios (RR) for dichotomous outcomes with 95% confidence intervals (CI). A summary of findings table of the main findings was constructed.Main ResultsForty-five RCTs were identified and, from these, 26 trials including a total of 1217 participants and 2120 implants were included. Three trials were at low risk of bias, 12 were at high risk of bias and for the remaining 11 the risk of bias was unclear. In nine of the included studies there were no prosthetic failures within the first year, with no implant failures in 7 studies and the mean rate of implant failure in all 26 trials was a low 2.5%. From 15 RCTs comparing immediate with convential loading there was no evidence of a difference in either prosthesis failure (RR 1.87; 95% CI 0.70 to 5.01; 8 trials) or implant failure (RR 1.65; 95% CI 0.68 to 3.98; 10 trials) in the first year, but there is some evidence of a small reduction in bone loss favouring immediate loading (MD -0.10 mm; 95% CI -0.20 to -0.01; P = 0.03; 9 trials), with some heterogeneity (Tau² = 0.01; Chi² = 14.37, df = 8 (P = 0.07); I² = 44%). However, this very small difference may not be clinically important. From three RCTs which compared early loading with conventional loading, there is insufficient evidence to determine whether or not there is a clinically important difference in prosthesis failure, implant failure or bone loss. Six RCTs compared immediate and early loading and found insufficient evidence to determine whether or not there is a clinically important difference in prosthesis failure, implant failure or bone loss. From the two trials which compared occlusal loading with non-occlusal loading there is insufficient evidence to determine whether there is a clinically important difference in the outcomes of prosthesis failure, implant failure or bone loss. We did not identify any trials which evaluated progressive loading of implants. Overall there was no convincing evidence of a clinically important difference in prosthesis failure, implant failure, or bone loss associated with different loading times of implants. More well-designed RCTs are needed and should be reported according to the CONSORT guidelines (www.consort-statement.org/).
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.