Randomized Controlled Trial Multicenter Study Comparative Study
Effect of defibrillation threshold testing on heart failure hospitalization or death in the Multicenter Automatic Defibrillator Implantation Trial-Cardiac Resynchronization Therapy (MADIT-CRT).
- Mehmet K Aktas, David T Huang, James P Daubert, Claudio D Schuger, Scott McNitt, Ilan Goldenberg, Arthur J Moss, and Wojciech Zareba.
- University of Rochester Medical Center, Rochester, New York 14642, USA. Mehmet_Aktas@urmc.rochester.edu
- Heart Rhythm. 2013 Feb 1;10(2):193-9.
BackgroundDefibrillation threshold (DFT) testing is commonly practiced at the time of implantable cardioverter-defibrillator (ICD) implant. The clinical consequence of ICD shocks delivered during DFT testing is unknown.ObjectiveThe purpose of this study was to determine the impact of ICD shocks and ICD shock energy level delivered during DFT testing in patients enrolled in the Multicenter Automatic Defibrillator Implantation Trial with Cardiac Resynchronization Therapy (MADIT-CRT) on clinical outcomes.MethodsPatients who underwent DFT testing within 1 month of device implant were categorized by the number of ICD shocks delivered during DFT testing (0, 1, 2, ≥3 shocks) and according to high vs low (>20 J vs ≤20 J) energy ICD shocks. Clinical outcomes consisting of heart failure (HF) or death, death alone, HF alone, and ventricular tachycardia or ventricular fibrillation were analyzed in each group.ResultsDFT testing was performed in 1,659 patients within 1 month of device implant (1 shock in 365 patients, 2 shocks in 896 patients, 3+ shocks in 398 patients). High-energy ICD shocks were delivered in 609 patients. Increasing number of ICD shocks during DFT testing was not associated with an increase risk for the primary end-point of HF or death or for any of the secondary end-points of HF alone, VT/VF alone, or death. Delivery of high vs low-energy ICD shocks was not associated with adverse clinical outcomes.ConclusionsIn patients with mild symptoms of HF, increasing number of ICD shocks and delivery of high energy ICD shocks during DFT testing was not associated with increased risk for HF or death or future VT/VF episodes.Copyright © 2013 Heart Rhythm Society. Published by Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.