-
Journal of hypertension · Mar 2005
Randomized Controlled Trial Comparative Study Clinical TrialBell or diaphragm in the measurement of blood pressure?
- Ilkka Kantola, Risto Vesalainen, Kari Kangassalo, and Antti Kariluoto.
- Department of Medicine, Turku University Central Hospital, Turku, Finland. ilkka.kantola@tyks.fi
- J. Hypertens. 2005 Mar 1;23(3):499-503.
BackgroundInternational guidelines have given diverse recommendations as to which side of the stethoscope should be used in the measurement of blood pressure.ObjectiveTo determine if there is any difference between the bell and the diaphragm sides of the ordinary acoustic stethoscope in the measurement of blood pressure.Design And MethodsWe compared, in random order, the bell and the diaphragm side of the ordinary acoustic stethoscope and also the effect of low- and high-frequency amplification with an electronic stethoscope in the measurement of blood pressure, in 250 adults.SettingDepartment of Medicine, Turku University Central Hospital.ResultsNo statistically significant difference was seen between the bell side and the diaphragm side of the acoustic stethoscope, either in systolic blood pressure (SBP; mean +/- SD 129.5 +/- 21.7 and 129.4 +/- 20.8 mmHg, respectively) or diastolic blood pressure (DBP; 77.0 +/- 12.0 and 77.1 +/- 12.0 mmHg, respectively). Both the low-frequency (130.7 +/- 22.5 mmHg) and the high-frequency (131 +/- 22.2 mmHg) amplification of systolic Korotkoff sounds yielded significantly greater values of SBP than were measured either with the bell (P = 0.008 compared with low frequency, P = 0.0005 compared with high frequency) or the diaphragm (P = 0.004 compared with low frequency, P = 0.0001 compared with high frequency). Low-frequency amplification of DBP (76.4 +/- 12.3 mmHg) yielded values significantly lower than those measured with the bell (P = 0.04) or the diaphragm (P = 0.01). Values from high-frequency amplification of DBP (77.2 +/- 12.3 mmHg) did not differ significantly from those measured with the acoustic stethoscope.ConclusionsBoth sides of the acoustic stethoscope give similar results in the measurement of office blood pressure and either side can be used in the reliable measurement of blood pressure.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.