- Forbes McGain, Katherine Maria Jarosz, Martin Ngoc Hoai Huong Nguyen, Samantha Bates, and Catherine Jane O'Shea.
- From the Departments of *Anaesthesia and †Intensive Care, Western Health, Melbourne, Victoria, Australia.
- A A Case Rep. 2015 Aug 1;5(3):47-50.
AbstractMuch waste arises from operating rooms (ORs). We estimated the practical and financial feasibility of an OR recycling program, weighing all waste from 6 ORs in Melbourne, Australia. Over 1 week, 237 operations produced 1265 kg in total: general waste 570 kg (45%), infectious waste 410 kg (32%), and recyclables 285 kg (23%). The achieved recycling had no infectious contamination. The achieved recycling/potential recycling rate was 285 kg/517 kg (55%). The average waste disposal costs were similar for general waste and recycling. OR recycling rates of 20%-25% total waste were achievable without compromising infection control or financial constraints.