• Neuromodulation · Jan 2011

    Simultaneous use of neurostimulators in patients with a preexisting cardiovascular implantable electronic device.

    • Yinn Cher Ooi, Steven Falowski, Daje Wang, Jack Jallo, Reginald T Ho, and Ashwini Sharan.
    • Thomas Jefferson University Hospital, Pennsylvania, PA 19107, USA.
    • Neuromodulation. 2011 Jan 1;14(1):20-5; discussion 25-6.

    ObjectNeurostimulation is widely accepted for the treatment of refractory Parkinson's disease, essential tremor, and chronic pain. The presence of a cardiovascular implantable electronic device (CIED) might be considered a contraindication for neurostimulators due to the possible interaction between the two devices. The purpose of this study is to report the feasibility and safety of concomitant use of neurostimulators and CIED, and to review surgical and clinical precautions needed to avoid possible interference between the two systems.MethodsA retrospective institutional review board approved chart review of six patients having both a neurostimulator(s) and a CIED was performed. Diagnosis included Parkinson's disease (two) and intractable pain (four). All implantable cardiac devices were set on bipolar sensing mode and bipolar stimulation was chosen for the neurostimulators. In general, both systems were implanted at sites seven inches apart. Electrocardiogram monitoring was observed throughout implantation. Patients were followed up for a mean period of 31.7 months (ranging from 14 to 67 months). An extensive chart review was done and cases from previous reports were compiled.ResultsIn all six patients, no acute events occurred during surgery with no interaction or interference noted during implantation of the second device. Subsequent follow-up visits continued to exhibit a lack of interference between the two systems, including normal electrocardiogram studies. Both systems were noted to function at optimal levels. An extensive literature review revealed 57 unique cases previously published reporting the simultaneous use of neurostimulators and a CIED in the same patient. A table summarizing previously cited cases from the literature is provided.ConclusionThe concomitant use of neurostimulator(s) and permanent pacemaker(s) can be safely performed. Permanent pacemaker should not be considered a general contraindication for neurostimulation therapy. Current literature lacks evidence to determine the safety of concomitant use of neurostimulator(s) and implantable cardioverter defibrillator(s).© 2010 International Neuromodulation Society.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…