• Anesthesia and analgesia · Jan 2011

    Comparative Study

    Current-distance relationships for peripheral nerve stimulation localization.

    • Jianming Li, Xuan Kong, Shai N Gozani, Riyi Shi, and Richard B Borgens.
    • Department of Basic Medical Science, School of Veterinary Medicine, Purdue University, West Lafayette, Indiana 47907, USA. jianming@purdue.edu
    • Anesth. Analg. 2011 Jan 1;112(1):236-41.

    BackgroundSuccessful peripheral nerve blocks require accurate placement of the injection needle tip before local anesthetic application. In this investigation, we experimentally reconstructed polarity-dependent (anode and cathode) stimulation maps using ex vivo and in vivo animal models.MethodsA novel ex vivo configuration (muscle-nerve composite) was first used to probe both cathodic and anodic stimulation characteristics. The electrophysiology (compound nerve action potential, CAP) of rat sciatic nerve was recorded at varying stimulation (monopolar electrode) distances and intensities. We repeated this methodology with an open dissection rat model that was more analogous to the clinical setting. Resultant data from the current sweeps were plotted as a 3-dimensional distance-stimulus-CAP map. These plots depict the minimum stimulation currents required for nerve activation and describe the expected electrophysiological outcomes as a function of distance and input stimulus intensity. The stimulation maps provide positional information relevant to clinical procedures such as nerve localization during regional anesthesia.ResultsCathodic stimulation produced a complex biphasic electrophysiological response. The CAP amplitude (with fixed current) increased as the electrode moved closer towards the nerve, but decreased upon close proximity or nerve contact. This phenomenon was dependent upon stimulation intensity and was observed in both ex vivo and in vivo models. Anodic stimulation produced a monotonic relationship, with the CAP increasing with closer electrode-to-nerve distances. Minimum extraneural activation thresholds were found to be 0.34 ± 0.11 mA (mean ± sd) and 0.63 ± 0.12 mA for cathode and anode stimulation, respectively. Intraneural thresholds were substantially lower, 0.12 ± 0.03 mA and 0.32 ± 0.09 mA, for cathode and anode, respectively.ConclusionCathodic stimulation may produce conduction block at close tip-to-nerve distances. In contrast, anodic stimulation elicited output characteristics that were predictable and more suitable for nerve localization. We believe anodic stimulation is a viable option at near-nerve distances, despite the increased current requirements. This hypothesis is a paradigm shift in stimulation nerve localization, which conventionally has been cathode based. The hypothesis should be clinically validated.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…