- Jace Wolfe, R Stanley Baker, and Mark Wood.
- Hearts for Hearing; and Otologic Medical Clinic at the Hough Ear Institute, 3525 NW 56th Street, Oklahoma City, OK 73112, USA. jace.wolfe@heartsforhearing.org
- Otol. Neurotol. 2013 Feb 1;34(2):227-32.
ObjectiveThis manuscript describes a case in which, based on clinical observations, we hypothesize that a change in a cochlear implant recipient's electrode impedance and performance was attributed to a change in the recipient's physiology rather than a device failure. Of particular note was the finding that electrode impedances decreased after a period of nonuse of the implant as well as after steroid treatment.Study DesignRetrospective single-subject case study review.SettingOutpatient clinic.PatientsThis paper describes outcomes for a 75-year-old male cochlear implant user.Intervention(S)A change in electrode impedance and a decrease in speech recognition were addressed through cochlear implant programming, periods of nonuse of the implant, provision of steroids, and bilateral cochlear implantation.Main Outcome Measure(S)The primary measures of interest were serial assessment of electrode impedance and speech recognition. Secondary measures included assessment of implant stimulation levels and electrophysiologic responses.ResultsElectrode impedances decreased (improved) after a period of nonuse of the implant as well as after provision of steroid treatment. Recipient performance also improved but did not return to baseline levels.ConclusionAtypical fluctuations in electrode impedance were observed with periods of CI use and nonuse. Additionally, after a 10-month period of constant fluctuation of electrode impedances with atypical morphology, electrode impedances stabilized to normal levels with a typical morphology within 3 days of steroid treatment. Given these observations, we hypothesized that the change in this recipient's electrode impedance as well as the decrease in this implant recipient's performance may be attributed to his physiology rather than to the device failure. Changes in electrode impedance accompanied by a decrease in this patient's performance were successfully addressed by a period of nonuse of the implant, provision of steroids, and an increase in the pulse width of the biphasic pulsatile signal used for stimulation. It should be noted that the results of this case are anecdotal in nature and may not apply to all cochlear implant recipients experiencing electrode impedance changes and/or deterioration in performance.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.