• J Vasc Interv Radiol · Aug 2004

    Comparative Study

    Power injection of contrast media via peripherally inserted central catheters for CT.

    • Douglas Coyle, Daniel Bloomgarden, Robert Beres, Shirish Patel, Shekhar Sane, and Emil Hurst.
    • Department of Radiology, St. Luke's Medical Center, 2900 West Oklahoma Avenue, Milwaukee, Wisconsin 53715, USA. doug.coyle@aurora.org
    • J Vasc Interv Radiol. 2004 Aug 1; 15 (8): 809-14.

    PurposeTo evaluate patient safety, catheter rupture rates, and computed tomography (CT) image quality when using peripherally inserted central catheters (PICCs) in vivo for the power injection of CT contrast media at standard injection rates.Materials And MethodsA prospective study to evaluate the safety and effectiveness of power injection of contrast media via indwelling PICCs was performed. Single-lumen and double-lumen polyurethane PICCs (5 F) were injected in vivo with contrast media for clinical CT examinations at injection rates ranging from 1 mL/sec to 4 mL/sec. Data collected included PICC rupture rate, patient complications, injection rate, peak injection pressure, PICC length, PICC age, and quality of contrast enhancement on the CT images.ResultsOne hundred ten power injections of PICCs for CT examinations were performed. There were 12 injections of single-lumen PICCs and 98 injections of double-lumen PICCs. The most common injection rate was 2 mL/sec, accounting for 89 of the 110 injections (81%). Two PICCs ruptured during power injection, both as a result of operator error. One of the PICCs that ruptured was clamped at the time of injection and the other one was kinked at its venous entry site. One additional PICC showed evidence of dysfunction; it ballooned without actually rupturing. No significant patient complications occurred. Contrast enhancement of the CT images was subjectively rated as average or above average in 95% of cases.ConclusionsContrast media can be power-injected via PICCs for routine CT examinations at a rate of 2 mL/sec, yielding satisfactory image quality without exposing patients to significant additional risk. Power injection rates greater than 2 mL/sec, as are typically used in CT angiography applications, were not fully evaluated by this study.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…