• Zh Vopr Neirokhir Im N N Burdenko · Jan 2003

    [Evaluation of the capacities of neurophysiological intraoperative monitoring in reconstructive surgery on the vertebral column].

    • O E Ryzhova, S A Tikhodeev, A A Vishnevskiĭ, S N Zhulev, and N A Beliakov.
    • Zh Vopr Neirokhir Im N N Burdenko. 2003 Jan 1 (1): 27-31; discussion 31-2.

    AimTo evaluate the capacities of neurosurgical intraoperative monitoring of somatosensory evoked potentials (SSEP) in reconstructive operations on the vertebral column.Materials And MethodsThe Center of Spinal Surgery examined 30 patients treated in February to July 2001. According to the diagnosis, the distribution was as follows: degenerative diseases of the vertebral column (80%), its tumors (10%), injury (7%), and inflammatory diseases (3%). Of them, 13 (43.3%) patients underwent anterolateral decompression of the dural sac of roots, 17 (56.7%) had traditional decompression of the dural sac and roots from the posterior access. The study was carried out on an 8-channel electrophysiological Viking-IV system (Nicolet, USA). Intraoperative SSEP monitoring was made by the routine procedure. The amplitude and latent time of subcortical peaks (P31) were determined at surgery. Intraoperative SSEPs were classified as defined with the American Electroencephalographic Society. The changes in the basic parameters of SSEP were also divided into transient (under 30 minutes) and permanent (above 30 minutes).ResultsTrue positive responses (significant changes in intraoperative SSEPs and the presence of postoperative neurological disorders) were 3.3% (1 patient); false positive ones (significant changes in intraoperative SSEPs without postoperative neurological disorders) were 23.3% (7 patients). False negative responses (normal intraoperative SSEPs and the presence of postoperative neurological disorders) were absent. The findings indicate that new postoperative neurological disorders should not be expected in patients with the clinical picture of mild neurological disorders if they have transient changes in the basic parameters of SSEPs that last at least 30 minutes. At the same time a risk group includes patients with severe neurological disorders since in these patients, compensatory capacities are primarily decreased and intraoperative exposures may result in early spinal circulatory decompensation. More frequent (every 10 minutes) recording of intraoperative SSEPs is also recommended for this group of patients is complicated surgical manipulations.Conclusions1. Neurophysiological intraoperative monitoring yields additional information for surgeons during an operation. 2. During intraoperative monitoring of SSEPs, it is necessary to assess any changes in the latter as true and to immediately find possible causes of these changes. 3. In patients with revealed spondylogenic spinal circulatory disorders and severe neurological disorders, even short-term changes in SSEPs should be assessed with particular carefulness before surgery.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.