    [Two cases of cutaneous erythema following spinal cord stimulation].

    • M Delaplace, F Maître, T Dufour, I Landrieux, P Gauthier, P Jebira, and E Estève.
    • Service de dermatologie, CHR d'Orléans, hôpital Porte-Madeleine, 1, rue Porte-Madeleine, 45032 Orléans cedex 1, France.
    • Ann Dermatol Vener. 2010 Apr 1; 137 (4): 297-300.

    IntroductionCutaneous complications following implantation of an electric system have been reported mainly after the implantation of pacemakers, cardiac defibrillators and morphine pumps. However, cutaneous complications following implantation of spinal cord stimulators are rarely described in the literature. Here we report two cases of cutaneous eruption at the spinal cord stimulation site, one involving foreign-body reaction to silicone in the neurostimulator electrodes or connector block and the other comprising contact dermatitis to silicone.Case ReportsCase 1: A 43-year-old woman had been implanted with a spinal cord stimulator. Four months after implantation, burning sensation and cutaneous inflammatory erythema were observed in the dorsolumbar region, with reduced efficiency of stimulation. Removal of the neurostimulator led to resolution of the cutaneous symptoms. Histopathological examination of the biopsy sample showed foreign-body granuloma formation. The same symptoms subsequently recurred on the surgical scar and histopathology showed granuloma formation in response to particles of silicone present in the connector. The cutaneous eruption subsided rapidly after excision. Case 2: In a 60-year-old man implanted with a spinal cord stimulator, pruriginous reticular erythema was rapidly observed on the skin just above the neurostimulator, with papules around the erythema. Histopathology of two cutaneous biopsies showed evidence of contact dermatitis. Skin-patch tests performed with components of the neurostimulator leads proved positive to two types of silicone after 72 hours. The eruption was successfully controlled using topical corticosteroid therapy.DiscussionReports of cutaneous eruptions after spinal cord stimulation are extremely rare. Here we report two different cutaneous reactions with two different pathophysiological mechanisms, both involving silicone. The first case is original because it is the first documented case of a foreign-body reaction involving granuloma formation in response to particles of silicone present in the components of a neurostimulator. The second case concerns contact dermatitis to silicone (present in the connector block and electrode sheaths).2010 Elsevier Masson SAS. All rights reserved.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…