Comparative Study
Optimizing compression: Comparing eccentric plate holes and external tensioning devices.
- Justin F Lucas, Mark A Lee, and Jonathan G Eastman.
- Department of Orthopedic Surgery, University of California at Davis, 4860 Y Street, Suite 3800, Sacramento, CA 95817, United States. Electronic address: Jflucas@ucdavis.edu.
- Injury. 2016 Jul 1; 47 (7): 1461-5.
ObjectiveElimination of interfragmentary motion in fracture fixation using plates to impart compression and promote primary bone healing through absolute stability has been well described as a reliable and successful method to treat simple transverse and short oblique fracture morphologies. Our hypothesis is that dynamic compression plating augmented by external compression techniques would produce and maintain a significantly greater amount of compression than using the plate alone.MethodsSimple transverse diayphyseal fractures were simulated in nine 4th generation composite bone models. A load cell was placed within the transverse fracture osteotomy and stabilized and compressed using either eccentric screw placement in a dynamic compression plate alone or augmented with an opposite segment Verbrugge clamp or articulated tensioning device (ATD) compressing using a screw outside of the plate. Dynamic plate compression was evaluated independently and in conjunction with the external compression techniques. Statistical analyses were carried out using a linear mixed effects model and pairwise comparisons between conditions with a significance set at a P-value <0.05.ResultsBoth of the external compression techniques (Verbrugge and ATD) achieved significantly higher compression than the plate compression technique alone with 78% (P<0.001) and 134% (P<0.001) more compression respectively. The measured compression across the osteotomy after screw application and removal of external compression decreases by 17% for the Verbrugge device (P=0.215) and by 22%, after removal of the ATD device (P=0.038). For both techniques, adding additional screws in eccentric (load) position further increases compression.ConclusionPlate compression is a reliable method for inducing compression across transverse and short oblique fractures. Augmenting plate compression technique with external compression techniques (Verbrugge clamp or ATD) allows for a significantly greater compressive load to be achieved. Compression lost after removal of the external compression device indicates that the maximal compression attainable across a fracture may not be reliably maintained with standard dynamic compression plating techniques.Copyright © 2016 Elsevier Ltd. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.