    Reproducibility and validity of a handheld spirometer.

    • R Graham Barr, Kimberly J Stemple, Sonia Mesia-Vela, Robert C Basner, Susan J Derk, Paul K Henneberger, Donald K Milton, and Brenda Taveras.
    • Department of Medicine, Columbia University Medical Center, New York, NY 10032, USA. rgb9@columbia.edu
    • Resp Care. 2008 Apr 1; 53 (4): 433-41.

    BackgroundHandheld spirometers have several advantages over desktop spirometers, but worries persist regarding reproducibility and validity of data from handheld spirometers. We undertook an independent examination of the EasyOne handheld spirometer.MethodsThe laboratory testing included reproducibility and validity testing with a waveform generator. We used standard American Thoracic Society waveforms for in-line testing, calibration adaptor testing, and testing during compression of the mouthpiece. The clinical testing involved repeated tests with 24 spirometry-naïve volunteers and comparison to spirometry results from laboratory (volume-sensing dry rolling seal) spirometer.ResultsThe EasyOne exceeded standard thresholds for acceptability with the American Thoracic Society waveforms. In-line testing yielded valid results from the EasyOne. Between the EasyOne and the reference spirometer readings the mean +/- SD difference was 0.03 +/- 0.23 L for forced vital capacity (FVC) and -0.06 +/- 0.09 L for forced expiratory volume in the first second (FEV(1)). The calibration adaptor showed no appreciable problems. Extreme compression of the mouthpiece reduced the measured values. In clinical testing the coefficients of variation and limits of agreement were, respectively, 3.3% and 0.24 L for FVC, 2.6% and 0.18 L for FEV(1), and 1.9% and 0.05 for the FEV(1)/FVC ratio. The EasyOne readings were lower than those from the reference spirometer; the differences were: -0.12 L for FVC, -0.17 L for FEV(1), and -0.02 for FEV(1)/FVC. The limits of agreement were within criteria for FVC but not for the FEV(1), possibly due to a training effect.ConclusionThe EasyOne spirometer yielded generally reproducible results that were generally valid, compared to the values from the laboratory spirometer. The use of the EasyOne in clinical, occupational, and research settings seems justified.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.