• Ann. Thorac. Surg. · Apr 2003

    Successful experience in bridging patients to heart transplantation with the MicroMed DeBakey ventricular assist device.

    • Ettore Vitali, Marco Lanfranconi, Elena Ribera, Giuseppe Bruschi, Tiziano Colombo, Maria Frigerio, and Claudio Russo.
    • Department of Cardiac Surgery A. De Gasperis, Niguarda Ca' Granda Hospital, Milan, Italy. evitali@ospedale-niguarda.it
    • Ann. Thorac. Surg. 2003 Apr 1; 75 (4): 1200-4.

    BackgroundPulsatile left ventricular assist devices are used with increasing frequency to bridge patients with end-stage heart failure to heart transplantation (HTx). Implantation of pulsatile devices is a cumbersome surgical procedure that is associated with major complications, such as bleeding, thromboembolism, and infection. Recently, a continuous axial flow left ventricular assist device (DeBakey ventricular assist device) has been introduced with the goal of reducing the incidence of major complications.MethodsWe reviewed our experience with 11 patients who received a DeBakey ventricular assist device axial flow pump for bridge to HTx from April 2000 through November 2001.ResultsTwo patients (18.2%) died of multiple-organ failure while on left ventricular assist device support. Bleeding requiring thoracotomy occurred in 2 patients (18.2%). One patient had a minor neurologic event, and one patient developed left ventricular assist device thrombosis, which was successfully treated without pump exchange. Renal failure developed in 1 patient and hepatic dysfunction in 2 patients. There were no instances of right heart failure. No device, pocket, or drive-line infections occurred. Nine patients (9 of 11, 81.8%) had HTx within 51 +/- 49 days (range, 11 to 141 days) after left ventricular assist device implant. One patient died 29 days after HTx because of acute rejection.ConclusionsThe continuous axial flow DeBakey ventricular assist device had reliable features, including a high rate of bridge to HTx. This device had low complication and system failure rates. We consider the DeBakey ventricular assist device a favorable alternative to pulsatile heart assist devices as a bridge to HTx.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…