Intensive care medicine · Dec 2009
Lung recruitment assessed by total respiratory system input reactance.
- Raffaele L Dellaca, Marie Andersson Olerud, Emanuela Zannin, Peter Kostic, Pasquale P Pompilio, Göran Hedenstierna, Antonio Pedotti, and Peter Frykholm.
- Dipartimento di Bioingegneria, Politecnico di Milano University, Piazza Leonardo da Vinci 32, 20133 Milan, Italy. raffaele.dellaca@polimi.it
- Intensive Care Med. 2009 Dec 1; 35 (12): 2164-72.
PurposeALI and ARDS are associated with lung volume derecruitment, usually counteracted by PEEP and recruitment maneuvers (RM), which should be accurately tailored to the patient's needs. The aim of this study was to investigate the possibility of monitoring the amount of derecruited lung by the forced oscillation technique (FOT).MethodsWe studied six piglets (26 +/- 2.5 kg) ventilated by a mechanical ventilator connected to a FOT device that produced sinusoidal pressure forcing at 5 Hz. The percentage of non-aerated lung tissue (V (tiss)NA%) was measured by whole-body CT scans at end-expiration with zero end-expiratory pressure. Respiratory system oscillatory input reactance (X (rs)) was measured simultaneously to CT and used to derive oscillatory compliance (C (X5)), which we used as an index of recruited lung. Measurements were performed at baseline and after several interventions in the following sequence: mono-lateral reabsorption atelectasis, RM, bi-lateral derecruitment induced by broncho-alveolar lavage and a second RM.ResultsBy pooling data from all experimental conditions and all pigs, C (X5) was linearly correlated to V (tiss)NA% (r (2) = 0.89) regardless of the procedure used to de-recruit the lung (reabsorption atelectasis or pulmonary lavage). Separate correlation analysis on single pigs showed similar regression equations, with an even higher coefficient of determination (r (2) = 0.91 +/- 0.07).ConclusionThese results suggest that FOT and the measurement of C (X5) could be a useful tool for the non-invasive measurement of lung volume recruitment/derecruitment.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.