Anesthesia and analgesia · Feb 2005
Does methemoglobin from oxidized hemoglobin-based oxygen carrier (hemoglobin Glutamer-200) interfere with lactate measurement (YSI 2700 SELECT Biochemistry Analyzer)?
- Stephen L Osgood, Jonathan S Jahr, Poonam Desai, Jessica Tsukamoto, and Bernd Driessen.
- Department of Anesthesiology, David Geffen School of Medicine at UCLA, PO Box 951778, Los Angeles, CA 90095-1778, USA.
- Anesth. Analg. 2005 Feb 1; 100 (2): 437-9.
AbstractIn this study, we validated the accuracy of lactate measurements (YSI 2700 SELECT glucose/lactate analyzer) in the presence of methemoglobin from an oxidized bag of hemoglobin-based oxygen carrier (Met-HBOC), hemoglobin glutamer-200 (Oxyglobin; Biopure Corp). Different combinations of concentrated L-lactate solution, pooled canine plasma, and Plasmalyte A were added to 4 sample groups (1%, 10%, 20%, and 40% Met-HBOC [1.3 g/dL]) to yield linear increases in lactate concentration in consecutive samples. The mean difference between measured and calculated lactate was -5.1 mg/dL (1% Met-HBOC), -5.8 mg/dL (10% Met-HBOC), -4.6 mg (20% Met-HBOC), and -8.5 mg/dL (40% Met-HBOC). The root mean square error was 6.5 mg/dL, 7.4 mg/dL, 6.8 mg/dL, and 10.3 mg/dL, respectively. The Bland-Altman correlation (r) was r = -0.94 (P = 0.01), r = -0.91 (P < 0.001), r = -0.90 (P < 0.001), and r = -0.94 (P < 0.001), respectively, where r = 0 for perfect agreement between measured and calculated values. Results indicate that true lactate levels in the presence of Met-HBOC are underestimated when measured by an YSI 2700 analyzer independent of the amount of Met-HBOC present. When interpreting lactate concentrations from a patient with a HBOC present in plasma, underestimation of true lactate levels may occur unrelated to methemoglobin concentrations.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.