• Surgery · Mar 1987

    Determination of optimal positive end-expiratory pressure by means of conjunctival oximetry.

    • H B Kram, P L Appel, A W Fleming, and W C Shoemaker.
    • Surgery. 1987 Mar 1; 101 (3): 329-34.

    AbstractA method for determining the optimal level of positive end-expiratory pressure (PEEP) by means of noninvasive conjunctival oxygen (PcjO2) monitoring and arterial blood gas analysis was developed from the pattern of changes in PcjO2 tension, invasive hemodynamic parameters, and oxygen transport variables during PEEP titration in a series of patients with adult respiratory distress syndrome. All patients had radial and pulmonary artery (PA) catheters inserted and blood volume was measured with 125I serum albumin before each study. During progressive increases in the level of PEEP, PcjO2 tensions reflected changes in both PaO2 and cardiac index (CI), depending on whether PEEP produced a significant decrease in CI. In patients with a stable CI, PcjO2 tensions tracked PaO2 values (rw = 0.92); in patients with a greater than a 15% decrease in CI, the conjunctival index, CjI (defined as the PcjO2/PaO2 ratio), tracked CI (rw = 0.87), excluding one patient with high cardiac output-septic shock and severe hypoxemia. PcjO2 correlated with PaO2 in the latter patient (r = 0.99) probably because conjunctival oxygen transport was limited by arterial oxygen content (PaO2 = 34 torr) rather than blood flow (CI greater than 6 L/min X m2). In patients with a greater than a 10% decrease in CI as a result of PEEP, the greater the decrease in CI, the better CjI values correlated with CI. We conclude that PcjO2 monitoring combined with repeated arterial blood gas analysis may be used to titrate PEEP therapy in patients with adult respiratory distress syndrome. In patients whose CjI significantly decreases because of PEEP, PA catheterization and measurement of cardiac output are indicated because of the likelihood of a significant (greater than 15%) decrease in CI. In the absence of a significant decrease in the CjI, optimum PEEP occurs at the level producing maximum PcjO2. It is hoped that by following the described algorithm, many patients will be spared the cost and morbidity of unnecessary PA catheterization.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…