• Surgical endoscopy · Nov 2011

    Laparoscopic implantation of neural electrodes on pelvic nerves: an experimental study on the obturator nerve in a chronic minipig model.

    • Benoit Rabischong, Demetrio Larraín, Pierre Rabischong, Revaz Botchorishvili, Georges Fraisse, Stephane Gallego, Philippe Gaydier, Jean Michel Chardigny, and Paul Avan.
    • CHU Clermont-Ferrand, Service de Gynecologie-Obstetrique et Medicine de Reproduction, CHU Estaing, 63003, Clermont-Ferrand Cedex 1, France. brabischong@chu-clermontferrand.fr
    • Surg Endosc. 2011 Nov 1; 25 (11): 3706-12.

    BackgroundLaparoscopic exposure of pelvic nerves has opened a new area in the field of neuromodulation. However, electrode design and material deterioration remain issues that limit clinical application. The objective of this study was to evaluate experimentally the laparoscopic implantation of different types of neural electrodes in order to achieve functional and selective electrical stimulation of pelvic nerves.MethodsThis was a prospective comparative study of the laparoscopic implantation and tolerance and efficacy of three monopolar cuff electrodes implanted on the obturator nerve in ten Göttingen minipigs (18-20 months old; 14.5-24 kg body weight). Animals were allocated to two groups. A 3-mm-diameter laparoscopic instrument was used during dissection of paravesical fossa and obturator nerve on both sides in order to minimize nerve damage. In all animals, a "split-cylinder" cuff electrode was implanted around the left obturator nerve. On the right side, a "lasso" cuff electrode was implanted in the first group and a "closed-cylinder" cuff was implanted in the second group. Electrical stimulation (0-5 V, 20 Hz) was performed for implanted electrodes on days 0, 7, 15, 30, 45, 60, and 90. Current intensity thresholds were identified by palpation of muscle contraction. Strength developed according to stimulation level and was measured using weight transducers.ResultsAll procedures were performed by laparoscopy. Mean operative times differed significantly among groups, the shortest being for split-cylinder electrodes (P = 0.0002). No electrical spread phenomena were observed. Initial thresholds were below 1.5 V (range = 0.5-1.3); however, a significant rise was observed, with time to a maximum of 2.7 V (P < 0.0001). Only split-cylinder electrodes remained functional after 3 months. The mean value of maximum strength remained stable during the study period (P = 0.21, NS).ConclusionsThe laparoscopic approach to implanting neuroprostheses seems to be very attractive. Furthermore, this approach could allow highly selective nerve stimulation to be achieved using simpler devices such as split-cylinder monopolar electrodes.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…