• Bmc Gastroenterol · Jan 2011

    A capillary blood ammonia bedside test following glutamine load to improve the diagnosis of hepatic encephalopathy in cirrhosis.

    • Saskia Ditisheim, Emiliano Giostra, Pierre R Burkhard, Nicolas Goossens, Gilles Mentha, Antoine Hadengue, and Laurent Spahr.
    • Gastroenterology and Hepatology, University Hospitals and Faculty of Medicine, 4, Rue Gabrielle Perret-Gentil, 1211 Geneva, Switzerland.
    • Bmc Gastroenterol. 2011 Jan 1; 11: 134.

    BackgroundHepatic encephalopathy (HE) is a frequent and severe complication of cirrhosis. A single determination of ammonia in venous blood correlates poorly with neurological symptoms. Thus, a better biological marker is needed.AimTo make a diagnosis of HE, we explored the value of ammonia in capillary blood, an equivalent to arterial blood, measured at bedside following an oral glutamine challenge.MethodsWe included 57 patients (age 56 yrs; M/F: 37/20) with cirrhosis (alcoholic = 42; MELD score 13.8 [7-29], esophageal varices = 38) and previous episodes of HE (n = 19), but without neurological deficits at time of examination, and 13 healthy controls (age 54 yrs). After psychometric tests and capillary (ear lobe) blood ammonia measurements, 20 gr of glutamine was administered orally. Tests were repeated at 60 minutes (+ blood ammonia at 30'). Minimal HE was diagnosed if values were > 1.5 SD in at least 2 psychometric tests. Follow-up lasted 12 months.ResultsThe test was well tolerated (nausea = 1; dizziness = 1). Patients showed higher values of capillary blood ammonia over time as compared to controls (0'-30'-60 minutes: 75, 117, 169 versus 52, 59, 78 umol/L, p < 0.05). At baseline, 25 patients (44%) had minimal HE, while 38 patients (67%) met the criteria for HE at 60 minutes (chi2: p < 0.01). For the diagnosis of minimal HE, using the ROC curve analysis, baseline capillary blood ammonia showed an AUC of 0.541 (CI: 0.38-0.7, p = 0.6), while at 60 minutes the AUC was 0.727 (CI: 0.58-0.87, p < 0.006). During follow-up, 18 patients (31%) developed clinical episodes of HE. At multivariate analysis, the MELD score (1.12 [1.018-1.236]), previous episodes of HE (3.2[1.069-9.58]), but not capillary blood ammonia, were independent predictors of event.ConclusionsIn patients with cirrhosis and normal neurological examination, bedside determination of ammonia in capillary blood following oral glutamine load is well tolerated and achieves a better diagnostic performance for minimal HE than basal capillary ammonia levels. However, capillary blood ammonia is a poor predictor of development of clinically overt HE.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…