-
J Spinal Disord Tech · Jul 2014
A biomechanical cadaveric study of a modified U-shaped interspinous distraction device.
- Weerasak Singhatanadgige, Pairat Tangpornprasert, Yongsak Wangroongsub, Pibul Itiravivong, and Noppachart Limpaphayom.
- *Department of Orthopedics, Faculty of Medicine, Chulalongkorn University †King Chulalongkorn Memorial Hospital, Thai Red Cross Society ‡Department of Mechanical Engineering, Faculty of Engineering, Chulalongkorn University, Bangkok, Thailand.
- J Spinal Disord Tech. 2014 Jul 1; 27 (5): 290-6.
Study DesignAn experimental study.ObjectiveTo analyze the effects of a modified U-shape interspinous distraction device (IDD) on the stability of a destabilized lumbar spine model.Summary Of Background DataThe use of IDD for treatment of lumbar spine pathology remains a subject of debate. A modified design of an IDD consisted of a titanium (Ti) U-shape dynamic stabilizer and a Ti tensioning wire loop was biomechanically tested.Materials And MethodsSix sets of cadaveric lumbar vertebrae levels 1-5 (L1-L5) were subjected to loads in flexion, extension, and lateral bending in the 4 following sequences: intact specimen, unilateral facetectomy and discectomy at L3-L4, insertion of the modified U-shape IDD at L3-L4, and pedicle screw fixation at L3-L4. The range of motion (ROM) of L3-L4 following modified U-shape IDD insertion was compared with that of the intact specimen. The ROM of the adjacent vertebrae (L2-L3 and L4-L5) following modified U-shape IDD insertion was compared with that after pedicle screw fixation. Statistical analysis was performed using the Wilcoxon signed-rank test.ResultsThe modified U-shape IDD decreased the ROM of a destabilized L3-L4 in all testing load (P<0.05). The stability of L3-L4 following the modified U-shape IDD insertion was restored to that of the intact specimen (P>0.05). The ROM at adjacent vertebrae after the modified U-shape IDD placement was similar to the ROM obtained after pedicle screw fixation at L3-L4.ConclusionsThe modified version of a U-shape IDD is effective in stabilizing an unstable segment of the lumbar spine. The device does not create deleterious effects on the adjacent vertebrae.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.