- Peter Schadewaldt, Bettina Nowotny, Klaus Strassburger, Jörg Kotzka, and Michael Roden.
- Institutes of Clinical Biochemistry and Pathobiochemistry, German Diabetes Center, Düsseldorf, Düsseldorf, Germany. schadewa@uni-duesseldorf.de
- Am. J. Clin. Nutr. 2013 Apr 1; 97 (4): 763-73.
BackgroundIndirect calorimetry (IC) with metabolic monitors is widely used for noninvasive assessment of energy expenditure and macronutrient oxidation in health and disease.ObjectiveTo overcome deficiencies in validity and reliability of metabolic monitors, we established a procedure that allowed correction for monitor-specific deviations.DesignRandomized comparative IC (canopy mode) with the Deltatrac MBM-100 (Datex) and Vmax Encore 29n (SensorMedix) was performed in postabsorptive (overnight fast >8 h) healthy subjects (n = 40). In vitro validation was performed by simulation of oxygen consumption (VO2) and carbon dioxide output (VCO2) rates by using mass-flow regulators and pure gases. A simulation-based postcalorimetric calibration of cart readouts [individual calibration control evaluation (ICcE)] was established in adults (n = 24).ResultsThe comparison of carefully calibrated monitors showed marked differences in VCO2 and VO2 (P < 0.01) and derived metabolic variables [resting energy expenditure (REE), respiratory quotient (RQ), glucose/carbohydrate oxidation (Gox), and fat oxidation (Fox); P < 0.001]. Correlations appeared to be acceptable for breath gas rates and REE (R(2) ~ 0.9) but were unacceptable for RQ (R(2) = 0.3), Gox, and Fox (R(2) = 0.2). In vitro simulation experiments showed monitor-dependent interferences for VCO2 and VO2 as follows: 1) within series, nonlinear and variable deviations of monitor readouts at different exchange rates; 2) between series, differences and unsteady variability; and 3) differences in individual monitor characteristics (eg, rate dependence, stability, imprecision). The introduction of the postcalorimetric recalibration by ICcE resulted in an adjustment of gas exchange rates and the derived metabolic variables with reasonable correlations (R(2) > 0.9).ConclusionsDifferential, metabolic, monitor-specific deviations are the primary determinants for lack of accuracy, comparability, and transferability of results. This problem can be overcome by the present postcalorimetric ICcE procedure.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.