• Prehosp Disaster Med · Dec 2017

    Comparative Study Controlled Clinical Trial

    A Comparison of Paramedic First Pass Endotracheal Intubation Success Rate of the VividTrac VT-A 100, GlideScope Ranger, and Direct Laryngoscopy Under Simulated Prehospital Cervical Spinal Immobilization Conditions in a Cadaveric Model.

    • Ryan Hodnick, Tony Zitek, Kellen Galster, Stephen Johnson, Bryan Bledsoe, and Daniel Ebbs.
    • 1Santa Fe Fire Department,Santa Fe,New MexicoUSA.
    • Prehosp Disaster Med. 2017 Dec 1; 32 (6): 621-624.

    ObjectiveThe primary goal of this study was to compare paramedic first pass success rate between two different video laryngoscopes and direct laryngoscopy (DL) under simulated prehospital conditions in a cadaveric model.MethodsThis was a non-randomized, group-controlled trial in which five non-embalmed, non-frozen cadavers were intubated under prehospital spinal immobilization conditions using DL and with both the GlideScope Ranger (GL; Verathon Inc, Bothell, Washington USA) and the VividTrac VT-A100 (VT; Vivid Medical, Palo Alto, California USA). Participants had to intubate each cadaver with each of the three devices (DL, GL, or VT) in a randomly assigned order. Paramedics were given 31 seconds for an intubation attempt and a maximum of three attempts per device to successfully intubate each cadaver. Confirmation of successful endotracheal intubation (ETI) was confirmed by one of the six on-site physicians.ResultsSuccessful ETI within three attempts across all devices occurred 99.5% of the time overall and individually 98.5% of the time for VT, 100.0% of the time for GL, and 100.0% of the time for DL. First pass success overall was 64.4%. Individually, first pass success was 60.0% for VT, 68.8% for GL, and 64.5% for DL. A chi-square test revealed no statistically significant difference amongst the three devices for first pass success rates (P=.583). Average time to successful intubation was 42.2 seconds for VT, 38.0 seconds for GL, and 33.7 for seconds for DL. The average number of intubation attempts for each device were as follows: 1.48 for VT, 1.40 for GL, and 1.42 for DL.ConclusionThe was no statistically significant difference in first pass or overall successful ETI rates between DL and video laryngoscopy (VL) with either the GL or VT (adult). Hodnick R , Zitek T , Galster K , Johnson S , Bledsoe B , Ebbs D . A comparison of paramedic first pass endotracheal intubation success rate of the VividTrac VT-A 100, GlideScope Ranger, and direct laryngoscopy under simulated prehospital cervical spinal immobilization conditions in a cadaveric model. Prehosp Disaster Med. 2017;32(6):621-624.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.