    Effect of Transcutaneous Electrode Temperature on Accuracy and Precision of Carbon Dioxide and Oxygen Measurements in the Preterm Infants.

    • Jessica F Jakubowicz, Shasha Bai, David N Matlock, Michelle L Jones, Zhuopei Hu, Betty Proffitt, and Sherry E Courtney.
    • Department of Pediatrics, University of Arkansas for Medical Sciences, Little Rock, AR. jmjakubowicz@uams.edu.
    • Respir Care. 2018 Jul 1; 63 (7): 900-906.

    BackgroundHigh electrode temperature during transcutaneous monitoring is associated with skin burns in extremely premature infants. We evaluated the accuracy and precision of CO2 and O2 measurements using lower transcutaneous electrode temperatures below 42°C.MethodsWe enrolled 20 neonates. Two transcutaneous monitors were placed simultaneously on each neonate, with one electrode maintained at 42°C and the other randomized to temperatures of 38, 39, 40, 41, and 42°C. Arterial blood was collected twice at each temperature.ResultsAt the time of arterial blood sampling, values for transcutaneously measured partial pressure of CO2 (PtcCO2 ) were not significantly different among test temperatures. There was no evidence of skin burning at any temperature. For PtcCO2 , Bland-Altman analyses of all test temperatures versus 42°C showed good precision and low bias. Transcutaneously measured partial pressure of O2 (PtcO2 ) values trended arterial values but had large negative bias.ConclusionTranscutaneous electrode temperatures as low as 38°C allow an assessment of PtcCO2 as accurate as that with electrodes at 42°C.Copyright © 2018 by Daedalus Enterprises.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.