• Respiratory care · Aug 2018

    Design and Function of a New Conical Positive Expiratory Pressure Device to Be Used During Exercise.

    • Chatchai Phimphasak, Chulee Ubolsakka-Jones, and David A Jones.
    • School of Physical Therapy, Faculty of Associated Medical Sciences, Khon Kaen University, Khon Kaen, Thailand.
    • Respir Care. 2018 Aug 1; 63 (8): 966-980.

    BackgroundA flow-dependent conical positive expiratory pressure (PEP) resistor incorporated into a oronasal mask was developed, which might reduce dyspnea and dynamic hyperinflation and increase exercise endurance for patients with COPD. We reported here the flow-pressure relationships and the safety and suitability of the device when used by healthy young and older subjects.MethodsThe flow-pressure relationships were determined for a range of resistors with different orifice diameters and cone lengths. A 1-cm conical-PEP device with a 6- or 7-mm orifice was used during a cycle exercise test (60% heart rate reserve) in 15 young (mean ± SD, 24.3 ± 3.9 y) and 12 older (mean ± SD, 64.4 ± 3.5 y) adults. Cardiopulmonary function and dyspnea were monitored for up to 10 min of exercise.ResultsFor a given flow, pressure decreased as the cone length and orifice size increased. A 1-cm cone with a 6 mm orifice generated pressures of 5.24 ± 0.17 cm H2O and 18.29 ± 0.34 cm H2O at flows of 0.5 and 0.9 L/s, while for a 7 mm orifice, pressures were 4.88 ± 0.13 cm H2O and 19.14 ± 0.10 cm H2O at flows of 0.5 and 1.1 L/s, such as might occur during exercise. The choice of orifice size for a subject depended on his or her estimated expiratory flow; larger flows required the larger orifice to generate an expiratory pressure of between 5 and 20 cm H2O. Breathing with the conical-PEP device did not affect exercise time, dyspnea, minute ventilation, heart rate, or blood pressure. The SpO2 was slightly lower and PETCO2 was somewhat higher than during control exercise, but the differences were not significant. There were no adverse physiological consequences.ConclusionsA conical-PEP device of 1-cm length with an orifice of 6 or 7 mm generates effective expiratory pressure for most subjects during exercise. There were no adverse effects in healthy young and older subjects, and the device is suitable for trials with patients with COPD. (ClinicalTrials.gov registration NCT 02788370.).Copyright © 2018 by Daedalus Enterprises.

      Pubmed     Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…

What will the 'Medical Journal of You' look like?

Start your free 21 day trial now.

We guarantee your privacy. Your email address will not be shared.