    Speeding the Detection of Vessel Cannulation: An In-Vitro Stimulation Study.

    • Matthew K Muffly, Andrew Ku, David R Drover, Samuel Rodriguez, Thomas J Caruso, Anne Ku, and Tsui Ban C H BCH From the Stanford University Medical Center, Stanford, California..
    • From the Stanford University Medical Center, Stanford, California.
    • Anesth. Analg. 2020 Jan 1; 130 (1): 159-164.

    BackgroundSome practitioners "prime" small IV angiocatheter needles with 0.9% sodium chloride-claiming this modification speeds visual detection of blood in the angiocatheter flash chamber on vessel cannulation.MethodsWe compared the time required for human blood to travel the length of saline-primed and saline-unprimed 24- and 22-gauge angiocatheter needles (Introcan Safety IV Catheter; B. Braun, Bethlehem, PA). A syringe pump (Medfusion 4000, Cary, NC) advanced each angiocatheter needle through the silicone membrane of an IV tubing "t-piece" (Microbore Extension Set, 5 Inch; Hospira, Lake Forest, IL) filled with freshly donated human blood. When the angiocatheter needle contacted the blood, an electrical circuit was completed, illuminating a light-emitting diode. We determined the time from light-emitting diode illumination to visual detection of blood in the flash chamber by video review. We tested 105 saline-primed angiocatheters and 105 unprimed angiocatheters in the 24- and 22-gauge angiocatheter sizes (420 catheters total). We analyzed the median time to visualize the flash using the nonparametric Wilcoxon rank sum test in R (http://www.R-project.org/). The Stanford University Administrative Panel on Human Subjects in Medical Research determined that this project did not meet the definition of human subjects research and did not require institutional review board oversight.ResultsIn the 24-gauge angiocatheter group, the median (and interquartile range) time for blood to travel the length of the unprimed angiocatheter needle was 1.14 (0.61-1.47) seconds compared with 0.76 (0.41-1.20) seconds in the saline-primed group (P = 0.006). In the 22-gauge catheter group, the median (interquartile range) time for blood to travel the length of the unprimed angiocatheter needle was 1.80 (1.23-2.95) seconds compared with 1.46 (1.03-2.54) seconds in the saline-primed group (P = .046).ConclusionsThese results support the notion that priming small angiocatheter needles, in particular 24-gauge catheters, with 0.9% sodium chloride may provide earlier detection of vessel cannulation than with the unprimed angiocatheter.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…