• BMC anesthesiology · Dec 2018

    Comparative Study

    A comparison of postoperative outcomes with PDA ligation in the OR versus the NICU: a retrospective cohort study on the risks of transport.

    • Lisa K Lee, Michelle Y Woodfin, Marissa G Vadi, Tristan R Grogan, Phillip J Ross, Richard L Applegate, and Marc Iravani.
    • Department of Anesthesiology and Perioperative Medicine, David Geffen School of Medicine, University of California, Los Angeles, 757 Westwood Plaza, Suite 3325, Los Angeles, CA, 90095-7403, USA. lklee@mednet.ucla.edu.
    • BMC Anesthesiol. 2018 Dec 22; 18 (1): 199.

    BackgroundAlthough patent ductus arteriosus (PDA) ligations in the Neonatal Intensive Care Unit (NICU) have been an accepted practice, many are still performed in the Operating Room (OR). Whether avoiding transport leads to improved perioperative outcomes is unclear. Here we aimed to determine whether PDA ligations in the NICU corresponded to higher risk of surgical site infection or mortality and if transport was associated with worsened perioperative outcomes.MethodsWe performed a retrospective cohort study of NICU patients, ≤37 weeks post-menstrual age, undergoing surgical PDA ligation in the NICU or OR. We excluded any infants undergoing device PDA closure. We measured the incidence of perioperative hypothermia, cardiac arrest, decreases in SpO2, hemodynamic instability and postoperative surgical site infection, sepsis and mortality.ResultsData was collected on 189 infants (100 OR, 89 NICU). After controlling for number of preoperative comorbidities, weight at time of procedure, procedure location and hospital in the mixed-effect model, no significant difference in mortality or sepsis was found (odds ratio 0.31, 95%CI 0.07, 1.30; p = 0.107, and odds ratio 0.40; 95%CI 0.14, 1.09; p = 0.072, respectively). There was an increased incidence of hemodynamic instability on transport postoperatively in the OR group (12.4% vs 2%, odds ratio 6.93; 95% CI 1.48, 35.52; p = 0.014).ConclusionPDA ligations in the NICU were not associated with higher incidences of surgical site infection or mortality. There was an increased incidence of hemodynamic instability in the OR group on transport back to the NICU. Larger multicenter studies following long-term outcomes are needed to evaluate the safety of performing all PDA ligations in the NICU.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…