-
Auris, nasus, larynx · Feb 2003
Flexibility of vestibulo-ocular reflex adaptation to modified visual input in human.
- Shoji Watanabe, Kosuke Hattori, and Izumi Koizuka.
- Department of Otolaryngology, St. Marianna University School of Medicine, 2-16-1, Sugao, Miyamae-ku, 216-8511, Kawasaki, Japan. s2wata@marianna-u.ac.jp
- Auris Nasus Larynx. 2003 Feb 1; 30 Suppl: S29-34.
AbstractThe vestibulo-ocular reflex (VOR) serves to keep images relatively stable on the retina. To maintain appropriate performance and minimize image slip throughout life, VOR is subjected to long-term adaptive regulation by visual input. It has been reported that adaptive changes in VOR gain (eye velocity/head velocity) are evoked either by fitting subjects with magnifying, miniaturizing, or reversing spectacles during normal behavior, or by moving a large visual field in or out of phase relative to the subject's head movement. The changes in VOR gain are frequency selective. Here, we examine the extent of VOR gain flexibility by causing VORs of similar direction to undergo different behavioral gain changes. Nine healthy adults participated in the study, ranging in age from 24 to 38 years (mean: 26 years) and with no history of neurotological symptoms. All subjects were clinically normal according to a screening battery that included combined neurologic and otologic physical examinations. Horizontal and vertical eye positions were recorded by bitemporal DC-coupled electro-oculography (EOG). The subject sat in a rotating chair. The axis of rotation of the body was always earth-vertical, with the interaural axis crossing the axis of rotation of the chair. The head was pointed 20 degrees downwards in all experiments and stabilized in this position using a chin rest. The chair was surrounded by a half-cylindrical optokinetic screen (78 cm in diameter) placed in front of the subject, onto which random dot patterns were projected. Goggles were used to ensure that the subject was in complete darkness during both pre- and postadaptation periods. The chair was rotated sinusoidally at maximum amplitude of 30 degrees or 60 degrees : for 30 degrees the stimulation was at 0.1, 0.2, 0.3, and 0.4 Hz; for 60 degrees it was at 0.1, 0.2, and 0.3 Hz. VOR adaptation was obtained by inducing a retinal slip velocity by short-term alteration of the visual input of the large field; this change was produced by a combination of sinusoidal head rotation and the random dot patterns. In each adaptation session, the sinusoidal head rotation was either at 0.1 or 0.3 Hz and the amplitude was 30 degrees. The random dot pattern was synchronized with sinusoidal head rotation in the same direction (x0 experiment) to make the retinal slip zero, and in the opposite direction to make the retinal slip twofold (x2 experiment). Therefore, a total of four adaptation protocols were tested. The subjects were asked to fixate on a single dot with the eyes straight-ahead in the x0 experiment, and follow it within random dot patterns in the x2 experiment. Each adaptation session lasted for 30 min. Two adaptation experiments were performed on each subject once per day. The averages of VOR gain and phase lag were calculated using Fourier analysis. Seven of the subjects who participated in the x2 adaptation experiment at 0.3 Hz and 30 degrees amplitude showed a steady increase of VOR gain within a couple of trials. One of the remaining two subjects showed a decrease in VOR gain in all the three trials, and the other subject showed a VOR gain increase in three trials and decrease in two trials. In the x2 adaptation experiment at 0.3 Hz and 30 degrees amplitude (peak velocity: 28 degrees /s), the percentage gain change ((post-pre)/pre) was 133% at the same stimulation and 100% at 0.4 Hz (peak velocity: 37 degrees /s). The gain change was 65% at 0.1 Hz and 60 degrees amplitude (peak velocity: 18 degrees /s), and 64% at 0.2 Hz and 60 degrees amplitude (peak velocity: 37 degrees /s). In the x1 adaptation experiment (30 degrees at 0.3 Hz), the percentage gain change was -62% under the same conditions, -50% at 0.1 Hz and 60 degrees amplitude, and -30% at 0.2 Hz and 60 degrees amplitude. No change of VOR gain was observed at other frequencies, and the subject was not adapted at 0.1 Hz and 30 degrees amplitude. The larger VOR gain increase in the x2 adaptation experiment for the faster head angular acceleration leads to the conclusion that the VOR gain mechanism can set vuite similar in terms of the head acceleration.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.