• J. Am. Soc. Nephrol. · Jan 2007

    Automated external defibrillators and survival from cardiac arrest in the outpatient hemodialysis clinic.

    • Ruediger W Lehrich, Patrick H Pun, Nadine D Tanenbaum, Stephen R Smith, and John P Middleton.
    • Department of Medicine, Division of Nephrology, Duke University, Box 3014 DUMC, Durham, NC 27710, USA.
    • J. Am. Soc. Nephrol. 2007 Jan 1; 18 (1): 312-20.

    AbstractAutomated external defibrillators (AED) have been recommended for use in outpatient dialysis clinics to improve outcomes from cardiac arrest, the most common cause of death in patients with ESRD. The effectiveness of this policy is unknown. The study cohort consisted of 43,200 hemodialysis patients in the US Gambro Healthcare System from 2002 to 2005. Of these, 729 patients who sustained an in-center cardiac arrest were identified. Baseline characteristics at the time of the event were compared between patients who underwent hemodialysis in clinics with and without an AED on site. Unadjusted survival and survival adjusted for potential confounders was measured using Cox proportional hazards regression models. Unadjusted survival at 30 d was 19 versus 15% (P = 0.12) and 9.5 versus 7.8% at 1 yr (P = 0.39) in the AED-present and AED-absent groups, respectively. AED presence was not associated with outcome in unadjusted analysis (hazard ratio [HR] 0.91; 95% confidence interval [CI] 0.78 to 1.07; P = 0.26). Univariable analysis identified age (HR 1.07 per decade; 95% CI 1.01 to 1.13), serum albumin (HR 0.91 per 0.7-mg/dl increase; 95% CI 0.82 to 1.01), and indwelling dialysis catheters (HR 1.21; 95% CI 1.02 to 1.42) as potential confounders. Medications including angiotensin-converting enzyme inhibitors or angiotensin receptor blockers, beta blockers, calcium channel blockers, other BP medications, aspirin, antibiotics, and antiarrhythmics were associated with survival and considered confounders. After controlling for case mix and confounders, AED presence was not associated with outcome (HR 0.98; 95% CI 0.82 to 1.18; P = 0.83). Presence of AED in the dialysis clinic is not sufficient by itself to improve the abysmal outcome from in-clinic cardiac arrest in hemodialysis patients in the United States.

      Pubmed     Free full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…