• J Bone Joint Surg Am · Oct 2018

    Continuous Near-Infrared Spectroscopy Demonstrates Limitations in Monitoring the Development of Acute Compartment Syndrome in Patients with Leg Injuries.

    • Andrew H Schmidt, Michael J Bosse, William T Obremskey, Robert V O'Toole, Eben A Carroll, Daniel J Stinner, David J Hak, Madhav Karunakar, Roman Hayda, Katherine P Frey, Junrui Di, Vadim Zipunnikov, Ellen MacKenzie, and Major Extremity Trauma Research Consortium (METRC).
    • Department of Orthopaedics, Hennepin Health System, Minneapolis, Minnesota.
    • J Bone Joint Surg Am. 2018 Oct 3; 100 (19): 1645-1652.

    BackgroundWe recorded measurements of muscle perfusion using near-infrared spectroscopy (NIRS) and intramuscular pressure (IMP) in a study designed to develop a decision rule for predicting acute compartment syndrome (ACS). The purpose of this study was to report our experience measuring NIRS data in the context of this broader investigation and to explore factors related to variations in data capture.MethodsOne hundred and eighty-five patients with lower-leg injuries had data consisting of continuous NIRS measurement of the O2 saturation in the anterior compartment of the injured limb and the contralateral (control) limb, and continuous IMP recording in the anterior and deep posterior compartments of the injured leg as part of their participation in an institutional review board-approved multicenter trial. All monitoring was done for a prescribed period of time. For both types of data, the percentage of valid data capture was defined as the ratio of the minutes of observed data points within a physiological range to the total minutes of expected data points. Clinically useful NIRS data required simultaneous data from the injured and control limbs to calculate the ratio. Statistical tests were used to compare the 2 methods as well as factors associated with the percent of valid NIRS data capture.ResultsFor the original cohort, clinically useful NIRS data were available a median of 9.1% of the expected time, while IMP data were captured a median of 87.6% of the expected time (p < 0.001). Excluding 46 patients who had erroneous NIRS data recorded, the median percentage was 31.6% for NIRS compared with 87.4% for IMP data (p < 0.00001). Fractures with an associated hematoma were less likely to have valid data points (odds ratio [OR], 0.53; p = 0.04). Gustilo types-I and II open fractures were more likely than Tscherne grades C0 and C1 closed fractures to have valid data points (OR, 1.97; p = 0.03).ConclusionsIn this study, NIRS data were not collected reliably. In contrast, IMP measurements were collected during >85% of the expected monitoring period. These data raise questions about the utility of current NIRS data capture technology for monitoring oxygenation in patients at risk of ACS.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…