-
Comparative Study
Cerebral Spinal Fluid collected by Lumbar Puncture has a higher diagnostic accuracy than collected by Ventriculostomy.
- Guilherme Finger, Paulo Valdeci Worm, Samir Cezimbra Dos Santos, do Nascimento Tobias Ludwig TL Neurosurgery Department, Cristo Redentor Hospital, Porto Alegre RS, Brazil; Graduate Program in Medicine: Surgical Sciences, Federal Univer, Pasquale Gallo, and Marco Antônio Stefani.
- Neurosurgery Department, Cristo Redentor Hospital, Porto Alegre RS, Brazil; Graduate Program in Medicine: Surgical Sciences, Federal University of Rio Grande do Sul, Porto Alegre RS, Brazil. Electronic address: guilhermefingermd@gmail.com.
- World Neurosurg. 2020 Jun 1; 138: e683-e689.
BackgroundPatients harboring an external ventricular drain (EVD) who develop signs of infection require screening for infection in the central nervous system (CNS). The cerebrospinal fluid (CSF) can be collected by the EVD or by lumbar puncture (LP). If only one sample is analyzed, the diagnosis might be dubious or false-negative. The objective of this study was to compare the diagnosis accuracy of CNS infection of CSF samples collected from EVD and LP.MethodsWe conducted a transversal study where data were prospectively collected from 2016 to 2019. Patients harboring EVD with signs of infection were submitted to the CSF analysis collected by LP and EVD. Diagnosis sensibility and results correlation were analyzed using the kappa index.ResultsThe 141 samples from LP and 141 samples from EVD were collected from 108 patients. Among the 282 samples, a total of 77 had infection. Seventy CSF samples from LP fulfilled infection criteria. However, only 32 EVD samples demonstrated infection. Among the 70 cases of infection based on the LP sample, 25 CSF samples collected from the EVD were also suggestive of infection; but in 45 patients only the CSF samples from LP met infection criteria. Seven patients had diagnosis of infection only in the EVD sample. The kappa correlation index of the results obtained from LP and EVD was 0.260 and the McNemar χ2 test was <0.01.ConclusionsThe CSF analysis exclusive from the EVD has a low sensibility and negative predictive value. CSF collected from LP has a sensibility 2.18 times higher than EVD.Copyright © 2020 Elsevier Inc. All rights reserved.
Notes
Knowledge, pearl, summary or comment to share?You can also include formatting, links, images and footnotes in your notes
- Simple formatting can be added to notes, such as
*italics*
,_underline_
or**bold**
. - Superscript can be denoted by
<sup>text</sup>
and subscript<sub>text</sub>
. - Numbered or bulleted lists can be created using either numbered lines
1. 2. 3.
, hyphens-
or asterisks*
. - Links can be included with:
[my link to pubmed](http://pubmed.com)
- Images can be included with:
![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
- For footnotes use
[^1](This is a footnote.)
inline. - Or use an inline reference
[^1]
to refer to a longer footnote elseweher in the document[^1]: This is a long footnote.
.