Neurocritical care
-
Ischemic stroke and intracranial hemorrhage (ICH) following left ventricular assist device (LVAD) placement are major causes of morbidity. The incidence and mortality associated with these events stratified by device type have not been systematically explored. ⋯ Ischemic stroke and ICH are common after LVAD placement, but heterogeneous event rates are reported in the literature. Given the high associated mortality, further prospective study is warranted.
-
Venous thromboembolism (VTE) prophylaxis in underweight patients with neurologic injury remains unaddressed by guidelines and primary literature. This study aimed to describe VTE prophylaxis strategies employed in this population and compare the impact of underweight and non-obese patients on thrombotic and bleeding events. ⋯ Current practice does not reflect dose reductions for neurologically injured, underweight patients. Caution should be considered when using increased doses of UFH in neurologically injured patients that are underweight and/or may be exposed to >150 units/kg/day of UFH. Continued assessment of VTE prophylaxis is needed to confirm these findings.
-
Noninvasive neuromonitoring is increasingly being used to monitor the course of primary brain injury and limit secondary brain damage of patients in the neurocritical care unit. Proposed advantages over invasive neuromonitoring methods include a lower risk of infection and bleeding, no need for surgical installation, mobility and portability of some devices, and safety. ⋯ We found 88 studies that were eligible for review including the methods transcranial ultrasound, electroencephalography, evoked potentials, near-infrared spectroscopy, bispectral index, and pupillometry. Noninvasive neuromonitoring cannot yet completely replace invasive methods in most situations, but has great potential being complementarily integrated into multimodality monitoring, for guiding management, and for limiting the use of invasive devices and in-hospital transports for imaging.
-
Many demographic and physiological variables have been associated with TBI outcomes. However, with small sample sizes, making spurious inferences is possible. This paper explores the effect of sample sizes on statistical relationships between patient variables (both physiological and demographic) and outcome. ⋯ Low power tests, generally achieved with small sample sizes, may produce misleading conclusions, especially when they are based only on p values and the dichotomized criteria of rejecting/not-rejecting the null hypothesis. We recommend reporting confidence intervals and effect sizes in a more complete and contextualized data analysis.
-
Multicenter Study
Prevention of Hypoxemia During Apnea Testing: A Comparison of Oxygen Insufflation And Continuous Positive Airway Pressure.
Apnea testing is an essential step in the clinical diagnosis of brain death. Current international guidelines recommend placement of an oxygen (O2) insufflation catheter into the endotracheal tube to prevent hypoxemia, but use of a continuous positive airway pressure (CPAP) valve may be more effective at limiting arterial partial pressure of O2 (PO2) reduction. ⋯ Both methods of O2 supplementation are associated with similar changes in arterial PO2 and PCO2. Performance of ABGs at regular intervals shortens apnea test duration and may avoid excessive pH reduction and consequent hemodynamic effects.