Anesthesia and analgesia
-
Anesthesia and analgesia · Jan 2011
Randomized Controlled Trial Multicenter Study Comparative StudyThe duration of residual neuromuscular block after administration of neostigmine or sugammadex at two visible twitches during train-of-four monitoring.
Adequate recovery from neuromuscular block (NMB) is imperative for the patient to have full control of pharyngeal and respiratory muscles. The train-of-4 (TOF) ratio should return to at least 0.90 to exclude potentially clinically significant postoperative residual block. Fade cannot be detected reliably with a peripheral nerve stimulator (PNS) at a TOF ratio >0.4. The time gap between loss of visual fade by using a PNS until objective TOF ratio has returned to >0.90 can be considered "the potentially unsafe period of recovery." According to our hypothesis the duration of this period would be significantly shorter with sugammadex than with neostigmine. ⋯ There is a significant time gap between visual loss of fade and return of TOF ratio >0.90 after reversal of a rocuronium block by neostigmine. Sugammadex in comparison with neostigmine allows a safer reversal of a moderate NMB when relying on visual evaluation of the TOF response.
-
Anesthesia and analgesia · Jan 2011
Comparative StudyDetermination of the precision error of the pulmonary artery thermodilution catheter using an in vitro continuous flow test rig.
Thermodilution cardiac output using a pulmonary artery catheter is the reference method against which all new methods of cardiac output measurement are judged. However, thermodilution lacks precision and has a quoted precision error of ± 20%. There is uncertainty about its true precision and this causes difficulty when validating new cardiac output technology. Our aim in this investigation was to determine the current precision error of thermodilution measurements. ⋯ In vitro testing of pulmonary artery catheters enabled us to measure both the random and systematic error components of thermodilution cardiac output measurement, and thus calculate the precision error. Using the Siemens monitor, we established a precision error of ± 15.3% for single and ± 13.0% for triplicate reading, which was similar to the previous estimate of ± 20%. However, this precision error was significantly worsened by using the Sirecust and Philips monitors. Clinicians should recognize that the precision error of thermodilution cardiac output is dependent on the selection of catheter and monitor model.
-
Anesthesia and analgesia · Jan 2011
Randomized Controlled Trial Comparative StudyAcupuncture in critically ill patients improves delayed gastric emptying: a randomized controlled trial.
Malnutrition remains a severe problem in the recovery of critically ill patients and leads to increased in-hospital morbidity and in-hospital stay. Even though early enteral nutrition has been shown to improve overall patient outcomes in the intensive care unit (ICU), tubefeed administration is often complicated by delayed gastric emptying and gastroesophageal reflux. Acupuncture has been successfully used in the treatment and prevention of perioperative nausea and vomiting. In this study we evaluated whether acupuncture can improve gastric emptying in comparison with standard promotility drugs in critically ill patients receiving enteral feeding. ⋯ We introduce a new protocol for acupuncture administration in the critical care setting. We demonstrated that this protocol was more effective than standard promotility medication in the treatment of delayed gastric emptying in critically ill patients. Acupoint stimulation at Neiguan (PC-6) may be a convenient and inexpensive option (with few side effects) for the prevention and treatment of malnutrition in critically ill patients.
-
Anesthesia and analgesia · Jan 2011
Randomized Controlled Trial Comparative StudyHand contamination of anesthesia providers is an important risk factor for intraoperative bacterial transmission.
We have recently shown that intraoperative bacterial transmission to patient IV stopcock sets is associated with increased patient mortality. In this study, we hypothesized that bacterial contamination of anesthesia provider hands before patient contact is a risk factor for direct intraoperative bacterial transmission. ⋯ The contaminated hands of anesthesia providers serve as a significant source of patient environmental and stopcock set contamination in the operating room. Additional sources of intraoperative bacterial transmission, including postoperative environmental cleaning practices, should be further studied.