Annals of neurology
-
Annals of neurology · Jun 1981
A comparison of stapedial reflex fatigue with repetitive stimulation and single-fiber EMG in myasthenia gravis.
The pattern of stapedial reflex fatigue in response to pulsed acoustic stimulation was measured and compared to results of repetitive nerve stimulation and single-fiber electromyography (EMG) in 89 patients with myasthenia gravis. Studies were also made on 22 patients with other neuromuscular disorders and 40 control subjects with no evidence of neuromuscular impairment. Stapedial reflex fatigue exceeded normal control values in 84% of the patients with myasthenia gravis. ⋯ Of 22 nonmyasthenic patients with neuromuscular disease tested, 6 had abnormal stapedial reflex fatigue according to our normal values, indicating that this form of testing also detects other diseases of the motor unit. The measurement of stapedial reflex fatigue is painless, is easy to perform, and requires minimal patient cooperation. Due to the relatively high occurrence of abnormal stapedial reflex fatigue in patients with myasthenia gravis, this procedure appears to have considerable potential value in screening and monitoring patients for the presence of defects in neuromuscular transmission.