Through a prospective study, we evaluated the efficacy of an integrated autotransfusion regimen comprised of predeposit-hemodiluition and intra and post-operative blood salvage in major orthopaedic surgery. ⋯ Cooperation among anaesthesis, transfusionists and surgeons in the application of an integrated autotransfusion regimen enabled us to treat 92% of our patients with only autotransfusion.
-
The control of intravascular volume (IVV) by continuous on-line measurement of protein concentration would optimise the patients' specific rate of ultrafiltration. To prove the accuracy of a refractometric device, plasma was continuously drawn by haemofiltration during 10 haemodialysis treatments of male patients. ⋯ The power of discrimination was 0.067% of IVV However, in vivo, the accuracy of IVV refractometric monitoring is reduced by interference factors such as sodium (0. 141 mV/mmol/L), glucose (0.034 mV/mg/dl) and triglycerides (-0.040 mV/mg/dl). Adjustment of the refraction data using sodium and glucose electrodes and plasma filters with a cut-off below the size of chylomicrons is recommended.
-
Frequently the only therapy for primary graft- and right heart failure, as well as low output syndrome from acute of chronic rejection, is implantation of a mechanical circulatory support system, until recompensation or retransplantation. At our institution, mechanical assist devices were implanted in 25 heart recipients for a cute rejection (n=9), primary graft failure (n=7), acute right heart failure (n=7), and chronic rejection with low output syndrome (n=2). Patients (pts) with primary graft failure (n=3) received an intraaortic balloon pump (IABP), one pt an IABP plus Abiomed-System for left ventricular support, one pt the Thoratec-System for biventricular support. ⋯ Two (8%) of 25 pts were retransplanted, 18 (72%) died in spite of mechanical support from multiple organ failure. The use of a mechanical assist device after heart transplantation is encouraging only in the case of early right heart failure, as well as primary and chronic graft failure. In view of the poor results, the use of mechanical assist devices should not be recommended in the case of heart failure caused by acute rejection.
-
Extracorporeal lung assist (ECLA) allowed surgical repair of a ruptured descending thoracic aorta to be performed in a patient with profound respiratory failure. Dense acute respiratory distress syndrome (ARDS) developed during his 15-day hospitalization at a regional trauma center. After transfer to a Level I facility, an additional injury was diagnosed: traumatic rupture of the aorta, contained within a pseudoaneurysm. ⋯ Cross-clamp time was 48 minutes. The patient was weaned from ECLA by the fifth postoperative day. To our knowledge, this is the first report of concurrent veno-venous pulmonary support with distal aortic perfusion.