J. Gastroenterol. Hepatol. · Jul 2020
Target-controlled propofol infusion with or without bispectral index monitoring of sedation during advanced gastrointestinal endoscopy.
Target-controlled infusion (TCI) uses averaged pharmacokinetic datasets derived from population samples to automatically control the infusion rate. Bispectral index (BIS) technology non-invasively measures levels of consciousness during surgical procedures. We compared the efficacy and safety of propofol TCI with or without BIS monitoring for sedation during advanced gastrointestinal endoscopy. ⋯ Mean infusion rates were higher in propofol TCI without BIS monitoring compared with propofol TCI with BIS during advanced gastrointestinal endoscopy. Endoscopists expressed satisfaction with BIS monitoring.