European journal of medical research
-
Case Reports
V-shaped double-row distal triceps tendon repair: a novel technique using unicortical button fixation.
This report was designed to present a novel technique combining suture anchor and unicortical button fixation for distal triceps tendon repair. ⋯ Technical description, case report, Level V.
-
Anterior tibial pseudoaneurysm is a rare complication after interlocking screw insertion in tibial nailing. We present the case of a 28-year-old male patient with this complication with a 6-week delay after tibial nailing of a right tibial fracture type 42-A1 of the Association for the Study of Internal Fixation (AO/ASIF) classification. On presentation to our emergency department, the patient's complaints were solemnly intermittent pain and occasional swelling of his proximal lower leg. ⋯ However, the patient sustained a temporal damage to the peroneal nerve after surgery. This case highlights the risk of a pseudoaneurysm of the anterior tibial artery after interlocking screw insertion as a rare but major complication of a routine surgical procedure. Early ultrasound diagnostics, CT angiography, or magnetic resonance (MR) angiogram should be performed to prevent the delay in diagnosis and treatment of such complications.
-
Review Meta Analysis
Safety of outpatient anterior cervical discectomy and fusion: a systematic review and meta-analysis.
Anterior cervical discectomy and fusion (ACDF) is one of the most prevalent spine surgeries and neurosurgical procedures performed to treat a variety of disorders in the cervical spine. Over the last several years, ACDF has been done in the outpatient setting for less invasive approaches and exposures, as well as modified anesthetic and pain management techniques. Despite the fact that it may be innocuous in other parts of the body, complications in the spine can literally be fatal. The objective of this article is to evaluate the safety of outpatient surgery compared with inpatient surgery in the cervical spine for adult patients. ⋯ In this study, outpatient surgery has a similar risk with inpatient surgery, and no difference of morbidity between outpatient and inpatient was found. Because of short operative time and moderate postoperative pain, we believe that outpatient cervical spine surgery is a safe and convenient alternative procedure, which also decrease the cost of care. Besides, postoperative complications including dysphagia and hematoma should be noticed.
-
Isolated radial neck fractures occur only in rare cases. The majority of cases are non-displaced or minimally displaced and can be treated conservatively. Conservative treatment, however, might result in secondary displacement and/or malunion. On the other hand, open reduction and internal fixation (ORIF) as standard surgical approach in adults is associated with non-union, implant-related complications and reduced range of motion. For isolated radial neck fractures with an intact radial head, the procedure of centromedullary pinning--as widely used in the treatment of paediatric radial neck fractures--might be an alternative operative technique in adults as well. The purpose of this retrospective case series therefore was to evaluate the functional outcome of radial neck fractures treated by intramedullary pinning. ⋯ In the present cohort, good to excellent results without relevant complications were seen. The technique of intramedullary pinning as described in the treatment of isolated radial neck fractures in children represents a suitable and reliable method in adults as well. In selected cases, this technique can be recommended as an alternative, minimal-invasive approach to the radial head plate osteosynthesis.
-
The rabbit disc model is useful for the study of intervertebral disc (IVD) degeneration and experimental therapeutic interventions. The annulotomy-induced disc models present several drawbacks, particularly an excessive disruption of disc integrity and a rapidly disc degeneration; therefore, this study sought to establish a minimal invasive annulotomy for induction of disc degeneration model, combined to annulus repair using implantation of a PLGA (poly lactic-co-glycolic acid) plug. ⋯ The minimally invasive approach for the creation of annular defects by an appropriately sized mini-Trephine is a suitable option for the study of disc degeneration in a rabbit model. Implantation of a suitable PLGA plug induced a successful repair of the annulus fibrosus within the degenerated disc, and retarded the degenerative process in the annular injury model.