British journal of anaesthesia
-
Critical illness polyneuropathy (CIP) is a recognized cause of muscle weakness and failure of weaning from a ventilator. In order to characterize the features of CIP, we have examined 28 consecutive surgical patients with severe sepsis using bedside electrophysiology. Of the 28 patients (median APACHE II score 31), 20 developed moderate to severe CIP, as shown by the presence of moderate to severe denervation activity on resting EMG. ⋯ Similar results were obtained from stimulation of the ulnar nerve. We conclude that CIP is a major complication in patients with severe sepsis and prolonged artificial ventilation. It predominantly involves motor fibres and thus markedly interferes with weaning from the ventilator.