J Formos Med Assoc
-
Meta Analysis
Effect of intraoperative neuromonitoring on recurrent laryngeal nerve palsy rates after thyroid surgery--a meta-analysis.
Though intraoperative nerve monitoring (IONM) during thyroid surgery has gained universal acceptance for localizing and identifying the recurrent laryngeal nerve (RLN), its role in reducing the rate of RLN injury remains controversial. In order to assess the effect of IONM during thyroid surgery, its value in reducing the incidence of RLN palsy was systematically evaluated. ⋯ Based on this meta-analysis, statistically significant differences were determined in terms of the incidences of total and transient recurrent laryngeal nerve palsy after using IONM versus recurrent laryngeal nerve identification alone during thyroidectomy. However, no statistically significant differences were identified regarding the incidence of persistent recurrent laryngeal nerve palsy between groups.