Respiratory care
-
Design and Function of a New Conical Positive Expiratory Pressure Device to Be Used During Exercise.
A flow-dependent conical positive expiratory pressure (PEP) resistor incorporated into a oronasal mask was developed, which might reduce dyspnea and dynamic hyperinflation and increase exercise endurance for patients with COPD. We reported here the flow-pressure relationships and the safety and suitability of the device when used by healthy young and older subjects. ⋯ A conical-PEP device of 1-cm length with an orifice of 6 or 7 mm generates effective expiratory pressure for most subjects during exercise. There were no adverse effects in healthy young and older subjects, and the device is suitable for trials with patients with COPD. (ClinicalTrials.gov registration NCT 02788370.).
-
ARDS has a high mortality in the acute setting, with long-term disability among disease survivors. In 1967, David Ashbaugh and colleagues first described the clinical features of ARDS, which were notably similar to the infantile respiratory distress syndrome. Half a century later, ARDS remains underrecognized and is associated with high mortality rates. ⋯ As a result, the task of identifying, consenting, and randomizing eligible patients within the enrollment window is challenging, further decreasing the number of subjects enrolled. Moreover, ARDS RCTs strictly adhere to lung-protective strategies, while ARDS observational studies continually demonstrate variable compliance. This review highlights the impact of patient- and trial-related factors on influencing mortality rates in ARDS observational studies and RCTs.
-
Randomized Controlled Trial
Development of Personalized Fitting Device With 3-Dimensional Solution for Prevention of NIV Oronasal Mask-Related Pressure Ulcers.
Pressure ulcers related to oronasal masks used with noninvasive ventilation (NIV), along with patient discomfort, occur due to improper fit of the mask. We developed a personalized fitting device using a 3-dimensional (3D) scanning solution to prevent the formation of NIV mask-related pressure ulcers. This study aimed to evaluate the effectiveness of the proposed personalized fitting device. ⋯ Personalized fitting devices that incorporate 3D scanning solutions may contribute to the prevention of NIV mask-related pressure ulcers and the reduction of discomfort.
-
Observational Study
Best Protocol for the Sit-to-Stand Test in Subjects With COPD.
Different protocols for the sit-to-stand test (STS) are available for assessing functional capacity in COPD. We sought to correlate each protocol of the STS (ie, the 5-repetition [5-rep STS], the 30-s STS, and the 1-min STS) with clinical outcomes in subjects with COPD. We also aimed to compare the 3 protocols of the STS, to verify their association and agreement, and to verify whether the 3 protocols are able to predict functional exercise capacity and physical activity in daily life (PADL). ⋯ The 1-min STS generated higher hemodynamic demands and correlated better with clinical outcomes in subjects with COPD. Despite the difference in speed performance and physiological demands between the 5-rep STS and 1-min STS, there was a good level of agreement among the 3 protocols. In addition, all 3 tests were able to identify subjects with low exercise capacity or preserved exercise capacity.
-
The aim of this work was to investigate the short- and long-term test-retest reliability of the 6-min walk distance (6MWD), peak heart rate, and nadir oxygen desaturation in idiopathic pulmonary fibrosis (IPF). ⋯ The 6MWD is a reproducible measure of exercise capacity in people with IPF. Whereas the nadir SpO2 may be accurately determined from one test, evaluating change in 6MWD with interventions may require 2 tests on each occasion. (ClinicalTrials.gov registration NCT0016828.).