Respiratory care
-
COPD is characterized by expiratory flow limitation, which results in symptomatic dyspnea and reduced exercise capacity. Changes in breathing mechanics mean the respiratory muscles are unable to respond to the ventilatory demands, increasing the sensation of dyspnea. A high-frequency oscillating device has been developed to improve dyspnea in patients with COPD. We conducted a feasibility trial to gain insight into the potential for recruitment, retention, and study design for a future randomized controlled trial. ⋯ This study design appeared feasible to proceed to a clinical effectiveness trial. The use of the device for 8 weeks showed a significant improvement in PEmax, PImax, and reduced symptomatic dyspnea on the MRC dyspnea score. The results of this study should encourage a randomized controlled trial.
-
Editorial Clinical Trial
Frequent Versus Infrequent Monitoring of Endotracheal Tube Cuff Pressures.
Currently there is no accepted standard of practice for the optimal frequency of endotracheal tube cuff pressure monitoring in mechanically ventilated patients. Therefore, we conducted a study to compare infrequent endotracheal tube cuff pressure monitoring (immediately after intubation and when clinically indicated for an observed air leak or due to tube migration) with frequent endotracheal tube cuff pressure monitoring (immediately after intubation, every 8 h, and when clinically indicated). ⋯ More frequent cuff pressure monitoring was not associated with any identifiable clinical outcome benefit.
-
Multicenter Study
High-Frequency Oscillatory Ventilation Use and Severe Pediatric ARDS in the Pediatric Hematopoietic Cell Transplant Recipient.
The effectiveness of high-frequency oscillatory ventilation (HFOV) in the pediatric hematopoietic cell transplant patient has not been established. We sought to identify current practice patterns of HFOV, investigate parameters during HFOV and their association with mortality, and compare the use of HFOV to conventional mechanical ventilation in severe pediatric ARDS. ⋯ In this large database of pediatric allogeneic hematopoietic cell transplant subjects who had acute respiratory failure requiring invasive mechanical ventilation for critical illness with severe pediatric ARDS, early use of HFOV was associated with improved survival compared to late implementation of HFOV, and the subjects had outcomes similar to those treated only with conventional mechanical ventilation.
-
Respiratory compromise is a leading contributor to global neonatal death. CPAP is a method of treatment that helps maintain lung volume during expiration, promotes comfortable breathing, and improves oxygenation. Bubble CPAP is an effective alternative to standard CPAP. We sought to determine the reliability and functionality of a low-cost bubble CPAP device designed for low-resource settings. ⋯ The low-cost bubble CPAP device evaluated in this study is comparable to a bubble CPAP system used in developed settings. Extensive clinical trials, however, are necessary to confirm its effectiveness.
-
Comparative Study
Inhalation Sedation in Subjects With ARDS Undergoing Continuous Lateral Rotational Therapy.
Isoflurane has shown better sedation control and potential benefits in patients with ARDS compared to propofol or midazolam, but the practical use during continuous lateral rotational therapy remains unknown. We therefore compared isoflurane with propofol and midazolam regarding sedation depth (per the Richmond Agitation-Sedation Scale), opioid consumption, lung function, and hemodynamics in patients treated with continuous lateral rotational therapy. ⋯ This study supports the feasibility of isoflurane sedation using continuous lateral rotational therapy.