Delay Between Actuation and Shaking of a Hydrofluoroalkane Fluticasone Pressurized Metered-Dose Inhaler.
Inhaled corticosteroids are used to treat pediatric asthma. The shaking of a pressurized metered-dose inhaler (pMDI) is required to ensure consistency of emitted dose. Delays between shaking and actuating the pMDI are frequent during administration of aerosols to children where a valved holding chamber is used. ⋯ Delays between shaking and actuating a corticosteroid suspension pMDI resulted in an increase in the emitted dose of the second actuation following the delay. This can be a common occurrence when doses are administered by a caregiver to a patient via a holding chamber. This should be addressed by practitioners educating patients and parents on proper inhaler use. (ClinicalTrials.gov registration NCT01714063.).
-
It has been suggested that use of a high-flow nasal cannula (HFNC) could be a first-line therapy for patients with acute hypoxic respiratory failure. The purpose of this study was to determine if protocolized use of HFNC decreases unplanned intubation and adverse outcomes in an ICU population. ⋯ Extubation to HFNC led to a significant decrease in pulmonary infections and bronchodilator therapy in Cohort 1 but did not reduce length of stay or rates of failed extubation. When HFNC was used early and per protocol (Cohort 2), ICU and hospital lengths of stay were reduced and HFNC was initiated more quickly when the need for respiratory support escalated.
-
Review
Patient-Reported Outcome Measures for Symptom Perception During a Cystic Fibrosis Exacerbation.
Symptom burden increases during pulmonary exacerbations of cystic fibrosis (CF), and patient-reported outcome measures (PROMs) are often used to evaluate symptoms as either primary or secondary outcomes. However, there is currently no guidance on the use of PROMs to assess symptom burden during pulmonary exacerbations. ⋯ Of the current PROMs used during CF pulmonary exacerbations, only 2 have been developed for this purpose, and only the CFRSD fulfilled all FDA guideline criteria. To date, there is no instrument that assesses exacerbation-specific symptom distress.
-
Multicenter Study
Reference Values for the 6-min Walk Distance (6MWT) in Healthy Children Aged 7 to 12 Years in Brazil: Main Results of the TC6minBRASIL Multi-Center Study.
Brazil is a country with great climatic, socioeconomic, and cultural differences that does not yet have a reference value for the 6-min walk test (6MWT) in healthy children. To avoid misinterpretation, the use of equations to predict the maximum walk distance should be established in each country. ⋯ Reference values were established for the 6MWT in healthy children aged 7-12 y in Brazil.
-
Oxygen cylinders are widely used both in hospital and prehospital care. Excessive or inappropriate FIO2 may be critical for patients with hypercapnia or hypoxia. Moreover, over-oxygenation could be deleterious in ischemic disorders. Supplemental oxygen from oxygen cylinder should therefore be delivered accurately. The aim of this study was to assess the accuracy of oxygen flows for oxygen cylinder in hospital and prehospital care. ⋯ This study shows good accuracy of oxygen flow delivered via oxygen cylinders. This accuracy was higher with dual stage. Single stage was also accurate, however, at low flow this accuracy is slightly less. Moreover, with single stage, when residual pressure decreases, the median value of delivered flow decreased.