Respiratory care
-
Mechanical ventilation is ubiquitous in critical care, and duration of ventilator liberation is variable and multifactorial. While ICU survival has increased over the last two decades, positive-pressure ventilation can cause harm to patients. Weaning and discontinuation of ventilatory support is the first step in ventilator liberation. ⋯ New tools such as diaphragmatic ultrasonography have begun to appear in the literature as a tool for outcome prediction. A number of systematic reviews with both meta-analysis and network meta-analysis that synthesize the literature on ventilator liberation have also been published in the last year. This review describes changes in performance, monitoring of spontaneous breathing trials, and evaluations of successful ventilator liberation.
-
Chronic hypercapnic respiratory failure is associated with high mortality. Although previous work has demonstrated a mortality improvement with high-intensity noninvasive ventilation in COPD, it is unclear whether a PCO2 reduction strategy is associated with improved outcomes in other populations of chronic hypercapnia. ⋯ Reduction in PCO2 from baseline for subjects with chronic hypercapnia treated with noninvasive ventilation was associated with improved survival. Management strategies should target the greatest attainable reductions in PCO2 .
-
The precise mechanisms driving poor exercise tolerance in patients with fibrotic interstitial lung diseases (fibrotic ILDs) showing a severe impairment in single-breath lung diffusing capacity for carbon monoxide (DLCO < 40% predicted) are not fully understood. Rather than only reflecting impaired O2 transfer, a severely impaired DLCO may signal deranged integrative physiologic adjustments to exercise that jointly increase the burden of exertional symptoms in fibrotic ILD. ⋯ A severely reduced DLCO in fibrotic ILD signals multiple interconnected derangements (cardiovascular impairment, an early shift to anaerobic metabolism, excess ventilation, inspiratory constraints, and hypoxemia) that ultimately lead to limiting respiratory (dyspnea) and peripheral (leg discomfort) symptoms. DLCO < 40%, therefore, might help in clinical decision-making to indicate the patient with fibrotic ILD who might derive particular benefit from pharmacologic and non-pharmacologic interventions aimed at lessening these systemic abnormalities.
-
Insufficient data are available about the noise produced by modern neonatal ventilators. We aimed to measure their noise under different ventilatory modes and parameters. ⋯ Modern ventilators often produce relevant noise, independent of the respiratory support modality, with acceptable noise levels being measured only outside the incubator. Better results were achieved with Servo-u, VN500, and Fabian family devices.