Saudi journal of anaesthesia
-
Spinal anesthesia has replaced general anesthesia in obstetric practice. Hemodynamic instability is a common, but preventable complication of spinal anesthesia. Preloading the circulation with intravenous fluids is considered a safe and effective method of preventing hypotension following spinal anesthesia. We had conducted a study to compare the hemodynamic stability after volume preloading with either Ringer's lactate (RL) or tetrastarch hydroxyethyl starch (HES) or succinylated gelatin (SG) in the patients undergoing cesarean section under spinal anesthesia. ⋯ RL which is cheap, physiological and widely available crystalloid can preload effectively and maintain hemodynamic stability well in cesarean section and any remnant hypotension can easily be manageable with vasopressor.
-
One of the methods proposed in cases of difficult airway management in children is using a supraglottic airway device as a conduit for tracheal intubation. The aim of this study was to compare the efficacy of the Air-Q Intubating Laryngeal Airway (Air-Q) and the Cobra Perilaryngeal Airway (CobraPLA) to function as a conduit for fiber optic-guided tracheal intubation in pediatric patients. ⋯ Both the Air-Q and CobraPLA can be used effectively as a conduit for fiber optic-guided tracheal intubation in children. However, the Air-Q proved to be superior due to a shorter intubation time and less airway morbidity compared with the CobraPLA.
-
Complex regional pain syndrome (CRPS) type 1 of the upper limb is a painful and debilitating condition. Interscalene brachial plexus block (ISB) in conjugation with other modalities was shown to be a feasible therapy with variable success. We reported a case of CRPS type 1 as diagnosed by International Association for the Study of Pain criteria in which pharmacological approaches failed to achieve adequate pain relief and even were associated with progressive dysfunction of the upper extremity. Single injection ISB, in combination with physical therapy and botulinum toxin injection, was successful to alleviate pain with functional restoration.
-
Case Reports
Partial airway obstruction following manufacturing defect in laryngeal mask airway (Laryngeal Mask Silken™).
Laryngeal mask (LM) airway is commonly used for securing airway in day-care surgeries. Various problems have been described while using LM airway. Out of those, mechanical obstruction causing airway compromise is most common. ⋯ There was a silicon band in upper one-third of shaft of LM airway. This band was made up of the same material as that of LM airway so it was not identifiable on external inspection of transparent shaft. We suggest that such as non-transparent laryngeal mask, a transparent LM airway should also be inspected looking inside the lumen with naked eyes or by using a probe to rule out any manufacturing defect before its insertion.