• Circulation · Jul 2014

    Randomized Controlled Trial Multicenter Study Comparative Study

    Efficacy of long detection interval implantable cardioverter-defibrillator settings in secondary prevention population: data from the Avoid Delivering Therapies for Nonsustained Arrhythmias in ICD Patients III (ADVANCE III) trial.

    • Axel Kloppe, Alessandro Proclemer, Angel Arenal, Maurizio Lunati, Martìnez Ferrer José Bautista JB From Medizinische Klinik II, Kardiologie und Angiologie, Berufsgenossenschaftliches Universitätsklinikum Bergmannsheil, Ruhr Universität , Ahmad Hersi, Marcin Gulaj, Maurits C E F Wijffels, Elisabetta Santi, Laura Manotta, Lorenza Mangoni, and Maurizio Gasparini.
    • From Medizinische Klinik II, Kardiologie und Angiologie, Berufsgenossenschaftliches Universitätsklinikum Bergmannsheil, Ruhr Universität Bochum, Bochum, Germany (A.K.); Azienda Ospedaliero Universitaria S. Maria della Misericordia, Udine, Italy (A.P.); Hospital General Universitario Gregorio Marañón, Madrid, Spain (A.A.); Azienda Ospedaliera Niguarda Ca' Granda, Milano, Italy (M.L.); Hospital de Txagorritxu, Vitoria (Álava), Spain (J.B.M.F.); College of Medicine, King Saud University, Riyadh, Saudi Arabia (A.H.); MSWiA Hospital, Bialystok, Poland (M. Gulaj); St. Antonius Ziekenhuis Hospital, Nieuwegein, Netherlands (M.C.E.F.W.); Medtronic Clinical Research Institute, Rome, Italy (E.S., L. Mangoni); Medtronic Clinical Research Institute, Sesto San Giovanni, Italy (L. Manotta); and Humanitas Research Hospital, Rozzano-Milano, Italy (M. Gasparini).
    • Circulation. 2014 Jul 22; 130 (4): 308-14.

    BackgroundThree trials demonstrated recently that a long detection window reduces implantable cardioverter-defibrillator (ICD) therapy in primary prevention patients. Avoid Delivering Therapies for Nonsustained Arrhythmias in ICD Patients III (ADVANCE III) was the only trial that enrolled both primary and secondary prevention patients.Methods And ResultsOf the 1902 patients enrolled in the ADVANCE III trial, 477 received a defibrillator for secondary prevention; 248 patients were randomly assigned to a long detection setting (30 of 40 intervals) and 229 to the nominal setting (18 of 24 intervals) for ventricular arrhythmias with cycle length ≤ 320 ms. Eight-five percent of patients were men, with a mean age of 65 ± 12 years, a previous history of ventricular fibrillation in 37% of the cases, and a mean ejection fraction of 38 ± 13%. The ICD device mix was 37% single chamber, 47% dual chamber, and 16% triple chamber. Over a median period of 12 months, the long detection period was associated with a 25% reduction in the number of overall therapies (115.6 versus 86.8 per 100 patient-years; incidence rate ratio, 0.75; 95% confidence interval, 0.61-0.93; P=0.008) and a 34% reduction in the number of shocks (rate per 100 patient-years, 51.2 versus 38.1; incidence rate ratio, 0.66; 95% confidence interval, 0.48-0.89; P=0.007). Appropriate therapies (89.7 versus 67.7; incidence rate ratio, 0.77; 95% confidence interval, 0.60-0.97; P=0.029) and appropriate shocks (37.1 versus 28.1; incidence rate ratio, 0.64; 95% confidence interval, 0.45-0.93; P=0.018) were also reduced.ConclusionsADVANCE III is the first randomized trial to assess a long detection window setting in ICDs in both primary and secondary prevention populations and demonstrates a reduction of overall therapies and shocks in the subgroup of secondary prevention patients. These data suggest that even the secondary prevention population may benefit from programming that combines a long detection period with antitachycardia pacing during charging.Clinical Trial Registration Urlhttp://www/clinicaltrials.gov. Unique identifier: NCT00617175.© 2014 American Heart Association, Inc.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?

    User can't be blank.

    Content can't be blank.

    Content is too short (minimum is 15 characters).

    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…