    Comparison of the LMA-classic with the new disposable soft seal laryngeal mask in spontaneously breathing adult patients.

    • André A J Van Zundert, Kristine Fonck, Baha Al-Shaikh, and Eric Mortier.
    • Department of Anesthesiology, Intensive Care and pain Therapy, Catharina Hospital, Eindhoven, The Netherlands.
    • Anesthesiology. 2003 Nov 1;99(5):1066-71.

    BackgroundThe laryngeal mask airway LMA-Classic has been used widely in clinical practice. A new disposable supraglottic airway device, the Soft Seal LM, has been introduced recently. In a randomized study, the authors compared the LMA-Classic and the disposable Soft Seal LM in terms of their clinical performance, cuff pressures during nitrous oxide anesthesia, position of the laryngeal mask in situ by fiberoptic evaluation, and morbidity in a wide range of routine general surgery procedures.MethodsA total of 200 adult patients were randomly assigned to a size 4 laryngeal mask in two equal-sized groups for airway management during surgery: (1) LMA-Classic (Intavent Orthofix Ltd., Maidenhead, Berkshire, United Kingdom); or (2) Soft Seal LM (Portex Ltd., Hythe, Kent, United Kingdom). Anesthesia was administered with fentanyl, propofol, nitrous oxide, oxygen, and sevoflurane. The variables studied were ease of insertion, fiberoptic view, time in situ, incidence of blood on the laryngeal mask at the time of removal, and the incidence of postoperative sore throat at 2 and 24 h. The laryngeal mask cuff pressures were measured continuously. Intracuff pressure limitation was not attempted.ResultsThe LMA-Classic and the Soft Seal LM showed similar clinical performances, as shown by their insertion time (successful insertion at first attempt was achieved within 20 s in 97% with LMA-Classic trade mark vs. 95% with Soft Seal LM), fiberoptic evaluation of the anatomic position of the laryngeal mask, and satisfactory anesthesia conditions. Laryngeal mask cuff pressures increased from 45 to 100.3 mmHg in the LMA-Classic and from 45 to 46.8 mmHg in the Soft Seal LM (P < 0.001). Macroscopic blood was seen on only four occasions in the LMA-Classic group. The incidence of sore throat was significantly increased at 2 h postoperatively when using the LMA-Classic, although there was no difference at 24 h after surgery.ConclusionsIn spontaneously breathing adult patients requiring a size 4 laryngeal mask airway, the new disposable Soft Seal LM device is an acceptable alternative to the reusable LMA-Classic trade mark, resulting in a good laryngeal seal and offering similar clinical performance. Cuff pressures increase substantially when the LMA-Classic is used but not when using the Soft Seal LM. There was less trauma to patients using the Soft Seal LM, as assessed by the incidence of sore throat in the early postoperative period.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…