• Ann Emerg Med · Jan 2007

    Randomized Controlled Trial

    Pilot study to evaluate the accuracy of ultrasonography in confirming endotracheal tube placement.

    • Sandra L Werner, Charles E Smith, Jessica R Goldstein, Robert A Jones, and Rita K Cydulka.
    • Department of Emergency Medicine, MetroHealth Medical Center/Cleveland Clinic Foundation, Cleveland, OH 44109, USA. swerner@metrohealth.org
    • Ann Emerg Med. 2007 Jan 1;49(1):75-80.

    Study ObjectiveVisualization of the vocal cords and end-tidal capnography are the usual standards in confirming endotracheal tube placement. Vocal cord visualization is, however, not always possible, and capnography is not 100% reliable and requires ventilation of the lungs to confirm placement. The goal of this study is to determine the accuracy of ultrasonography for detecting endotracheal tube placement into the trachea and esophagus in real time.MethodsThis was a prospective, randomized, controlled study. Eligible patients were adults undergoing elective surgery requiring intubation. Exclusion criteria were a history of difficult intubation, abnormal airway anatomy, aspiration risk factors, and esophageal disease. Thirty-three patients were enrolled. After induction of anesthesia and neuromuscular blockade, the anesthesiologist placed the endotracheal tube in the trachea and esophagus in random order with direct laryngoscopy. During the intubations, a high-frequency, linear transducer was placed transversely on the neck at the suprasternal notch. Two emergency physicians, blinded to the order and performance of the intubations, independently recorded the location of the endotracheal tube according to the real-time ultrasonographic image. A 2-by-2 table was used to calculate sensitivity and specificity of the emergency physicians' ability to detect placement of the endotracheal tube.ResultsFor each physician, the sensitivity for identifying the first intubation as tracheal was 100% (95% confidence interval [CI] 77% to 100%) with a specificity of 100% (95% CI 82% to 100%). One endotracheal tube was unintentionally placed twice in the esophagus, but both tube placements were identified as esophageal by the emergency physicians.ConclusionIn this pilot study, 2 emergency physicians experienced in ultrasonography accurately detected placement of endotracheal tubes during intubation with ultrasonography in select patients in the controlled environment of the operating room. Future studies should examine the use of ultrasonography to visualize endotracheal tube placement in real time by emergency physicians with less ultrasonographic training; use of the technique in the emergency department on a wider range of patients, including patients with difficult airways; and assessment of the utility of ultrasonography in confirmation of endotracheal tube position in already intubated patients.

      Pubmed     Full text   Copy Citation     Plaintext  

      Add institutional full text...

    Notes

     
    Knowledge, pearl, summary or comment to share?
    300 characters remaining
    help        
    You can also include formatting, links, images and footnotes in your notes
    • Simple formatting can be added to notes, such as *italics*, _underline_ or **bold**.
    • Superscript can be denoted by <sup>text</sup> and subscript <sub>text</sub>.
    • Numbered or bulleted lists can be created using either numbered lines 1. 2. 3., hyphens - or asterisks *.
    • Links can be included with: [my link to pubmed](http://pubmed.com)
    • Images can be included with: ![alt text](https://bestmedicaljournal.com/study_graph.jpg "Image Title Text")
    • For footnotes use [^1](This is a footnote.) inline.
    • Or use an inline reference [^1] to refer to a longer footnote elseweher in the document [^1]: This is a long footnote..

    hide…